City of Alma (AR)
Spot something wrong?
These change with code cycles. If a requirement here is out of date or missing, tell us and we'll fix it.
Report a correction NEC Code Version2020
Wet Stamps RequiredNone
Fire Setback EnforcedYes
Codes
- NEC Code Version
- 2020
- Code List
- 2021 ARKANSAS FIRE CODE 2020 NATIONAL ELECTRIC CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- Yes
- New Planset Required For Module Swap
- No
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- None
- Structural Calculations Required
- No
Fire setbacks
- Fire Setback Enforced
- Yes
- Setback Notes
- 36 in from edge on all sides 18 in on _both_ sides of ridges and valleys.
Structural & loads
- Wind Speed
- 90
- Snow Load
- 10
- Reducible Snow Load Allowed
- Yes
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Allowed POI
- PV Breaker,Load Side Taps,Line Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- No
- ESS Notes
- Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Custom Placards Required
- Yes
- Placards Notes
- Custom placard to designs
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim