City of Alma (AR)

Arkansas Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2020
Wet Stamps RequiredNone
Fire Setback Enforced1

Codes

NEC Code Version
2020
Code List
2021 ARKANSAS FIRE CODE 2020 NATIONAL ELECTRIC CODE
ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

Revision Required
1
New Planset Required For Module Swap
0

Stamps

Ee Stamp Required On SLD
No
Wet Stamps Required
None
Structural Calculations Required
No

Fire setbacks

Fire Setback Enforced
1
Setback Notes
36 in from edge on all sides 18 in on _both_ sides of ridges and valleys.

Structural & loads

Wind Speed
90
Snow Load
10
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Minimum Ground On Roof
#10

Electrical

Allowed POI
PV Breaker,Load Side Taps,Line Side Taps,Meter Adapter
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
0.91

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes
Standard
Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Custom Placards Required
1
Placards Notes
Custom placard to designs

Ground mount

Ground Mount Fencing Required
Mesh/Scrim