City of Alma (AR)
NEC Code Version2020
Wet Stamps RequiredNone
Fire Setback Enforced1
Codes
- NEC Code Version
- 2020
- Code List
- 2021 ARKANSAS FIRE CODE 2020 NATIONAL ELECTRIC CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 1
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- None
- Structural Calculations Required
- No
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
- 36 in from edge on all sides 18 in on _both_ sides of ridges and valleys.
Structural & loads
- Wind Speed
- 90
- Snow Load
- 10
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Allowed POI
- PV Breaker,Load Side Taps,Line Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
- Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Custom Placards Required
- 1
- Placards Notes
- Custom placard to designs
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim