City of Blytheville (AR)
NEC Code Version2017
Fire Setback Enforced1
Codes
- NEC Code Version
- 2017
- Code List
2021 INTERNATIONAL BUILDING CODE (IBC) 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) 2021 INTERNATIONAL MECHANICAL CODE (IMC) 2021 ARKANSAS PLUMBING CODE (APC) 2018 INTERNATIONAL FUEL GAS CODE (IFGC) 2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC) 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC) 2021 ARKANSAS FIRE PREVENTION CODE (AFPC) 2017 NATIONAL ELECTRICAL CODE (NEC)
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Fire setbacks
- Fire Setback Enforced
- 1
- Ridge Setback
- 18
- Rake Setback
- 3
- Hip Valley Setback
- 18
- Setback Notes
3 feet from rakes
18" from ridge and valleys
Structural & loads
- Wind Speed
- 90
- Wind Notes
EXPOSURE C
- Snow Load
- 10
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Allowed POI
- PV Breaker,Line Side Taps,Load Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim