City of Coolidge (AZ)
Codes
- NEC Code Version
- 2017
- Fire Code Version
- 2018 Building Code
- Code List
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL RESIDENTIAL CODE
2018 INTERNATIONAL MECHANICAL CODE
2018 INTERNATIONAL PLUMBING CODE
2018 UNIFORM PLUMBING CODE
2018 INTERNATIONAL FUEL GAS CODE
2018 INTERNATIONAL ENERGY CONSERVATION CODE
2018 INTERNATIONAL EXISTING BUILDING CODE
2018 INTERNATIONAL SWIMMING POOL AND SPA CODE
2017 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- How Many Plansets Required
- 2
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 90
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Allowed POI
- Load Side Taps,PV Breaker,Meter Adapter,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 75
- De Rating Ampacity
- 0.87
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Use min. 8-AWG wire on all battery systems. PM required. Use EATON B-LINE 011 METER SOCKET 125A 4 JAW 1PH NEMA 3R (top feed).
No published information about battery placement.
- Separate ESS Disconnect Required
- Local Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Add copy of sold contract to end of planset "Job Valuation"
- Electrical Diagram
Backfeed Breaker needs to be called out as either 22k rated, or series rated. A note saying either/or is not sufficient. AHJ wants to know which one.
22k AIC fully rated to comply with 2005 NEC 110.9 -or- 10k AIC series rated to comply with NEC 240.86.
(USE THIS NOTE BELOW ON YOUR THREE/SINGLE LINE. FILL IN THE ## WITH THE CORRECT VALUES PER YOUR PROJECT. Use the site audit photos to determine the ratings of your main breaker and branch circuit breakers):
AVAILABLE FAULT CURRENT: ##### (should be around 14,318)
MAIN BREAKER AIC: ## kA
BRANCH BREAKER AIC: ##kA
COMBINATION RATING PER PANEL LABEL: ## kA
-PLUG-IN-TYPE OVERCURRENT PROTECTION DEVICES OR PLUG-IN TYPE MAIN LUG ASSEMBLES THAT ARE BACKFED AND USED TO TERMINATE FIELD-INSTALLED UNGROUNDED SUPPLY CONDUCTORS SHALL BE SECURED IN PLACE BY AN ADDITIONAL FASTENER THAT REQUIRES OTHER THAN A PULL TO RELEASE THE DEVICE FROM THE MOUNTING MEANS ON THE PANEL.
-If the utility is Hohokam Irrigation and Power, reference ED2's fault current in the file section --If the utility is SCIP, send an email to ; provide the customer's address, the size (current) and voltage of the MSP and main breaker, along with the phase. That information gets forwarded to SCIP's engineer and after a few days, they'll send back an email.
-The SRP and APS Fault current documents were also uploaded as a reference Please check file section.
-If adding a subpanel, provide a panel schedule with breaker sizes and AIC ratings and a load calculation for the sub-panel.
-N-G BOND AT AC DISCO AND MSP
- Custom Placards Required
- 0
- Non Standard Planset Requirements
- Single Line Diagram
- Non Standard Revision Requirements
- If secondary revision exists, first revision letter and all clouding must be removed
Ground mount
- Ground Mount Fencing Required
- No