City of Cottonwood (AZ)

Arizona Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2023
Fire Code Version2018 Building Code
SolarAPP+ StatusAdopted
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1

Codes

NEC Code Version
2023
Fire Code Version
2018 Building Code
Code List

2018 INTERNATIONAL BUILDING CODE (IBC)

2018 INTERNATIONAL RESIDENTIAL CODE (IRC)

2023 NATIONAL ELECTRICAL CODE (NEC)

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

SolarAPP+ Status
Adopted
Any SolarAPP+ Restrictions
1
SolarAPP+ Restrictions
Existing Systems,Trenching
How Many Plansets Required
2
Revision Required
1
Rough Inspection
None
New Planset Required For Module Swap
0

Stamps

Wet Stamps Required
Digital Structural
Structural Calculations Required
Yes
Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
1
Setback Notes
  • The pathway should be not less than 36” wide measured from the edge of the solar array.
  • There should be a minimum of 36” of clearance at the ridgeline to allow for smoke ventilation.
  • This guideline does not apply to non-habitable structures without concealed attic/roof spaces. Examples of non-habitable structures include, but are not limited to, parking shade structures, carports, solar trellises, etc.

Structural & loads

Wind Speed
110
Wind Notes

Exposure Category B

Snow Load
20
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Structural Notes


Minimum Ground On Roof
#10

Electrical

Electrical Load Calcs Required
Derates
Allowed POI
Load Side Taps,PV Breaker,Meter Adapter,Line Side Taps
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
0.91

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Standard

Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Plan Set Requirements


Electrical Diagram

Standard

Custom Placards Required
0
Placards Notes
All signage and markings required by NEC 690 shall be a phenolic or metallic plate or other similar material engraved in block letters at least 1/4" high and suitable for the environment and application. The letters and the background shall be in contrasting colors. Screws or rivets shall be used to affix an identification plate to the equipment or enclosure. In addition to the signage and markings required in NEC 690 an Identification Plate is needed to provide emergency responders with appropriate warning regarding the solar electric system and must comply with the following: • Identification Plate text: “WARNING: PHOTOVOLTAIC POWER SOURCE” • Red background, white lettering • Minimum 3/8” letter height, all capital letters • Arial or similar font, non‐bold • Reflective, weather resistant material • The marking should be placed on the exterior of structure adjacent to the meter and within the main service disconnect. If the main service disconnect is operable with the service panel closed, then the marking should be placed on the outside cover.

Ground mount

Ground Mount Fencing Required
Mesh/Scrim
Compiled from public records, 2026. Requirements change with code cycles and local amendments. Verify with the City of Cottonwood (AZ) building department before you rely on this, and treat it as a research head start, not a ruling. Getting quotes? Run them through the quote checker first.