City of Douglas (AZ)
Codes
- NEC Code Version
- 2005
- Fire Code Version
- 2018 Building Code
- Code List
2006 INTERNATIONAL BUILDING CODE
2006 INTERNATIONAL RESIDENTIAL CODE
2005 NATIONAL ELECTRICAL CODE
2006 INTERNATIONAL CODE COUNCIL ELECTRICAL CODE
2006 INTERNATIONAL PLUMBING CODE
2006 INTERNATIONAL FUEL GAS CODE
2006 INTERNATIONAL MECHANICAL CODE
2006 INTERNATIONAL EXISTING BUILDING CODE
2006 INTERNATIONAL ENERGY CONSERVATION CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 3
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- None
- Structural Calculations Required
- No
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 5
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
- Marking no structural needed based on this job will update once we receive the feedback: (a past project Del Mar- 502 N Elizabeth ave) 1/26/2021 - BC
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,PV Breaker,Meter Adapter,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Below are a few APS requirements that Miguel has mentioned for Douglas jobs: All solar jobs will need a minimum 200A service 3ft clearance from windows and doors Equipment can't be below or above windows They would like the equipment towards the front of the house, preferably on the side but if that doesn't work it can be on the front of the house. Provide elevation drawings from front, sides and rear as well that would represent the visual of the array panels as proposed for mounting
- Electrical Diagram
Standard
- Custom Placards Required
- 0
- Non Standard Planset Requirements
- BOS Elevation
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim