City of Maricopa (AZ)
Codes
- NEC Code Version
- 2017
- Fire Code Version
- 2018 Building Code
- Code List
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL RESIDENTIAL CODE
2018 INTERNATIONAL MECHANICAL CODE
2018 INTERNATIONAL PLUMBING CODE
2018 INTERNATIONAL FUEL GAS CODE
2018 INTERNATIONAL ENERGY CONSERVATION CODE
2018 INTERNATIONAL EXISTING BUILDING CODE
2018 INTERNATIONAL SWIMMING POOL AND SPA CODE
2017 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 2
- Revision Required
- 1
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- None
- Structural Calculations Required
- No
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 110
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
- 5/19 - Project submitted with no stamp requests (DH)
- Minimum Ground On Roof
- #8
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,Load Side Taps,PV Breaker,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.87
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Use min. 8-AWG wire on all battery systems. Site Plan must show location of RAPID SHUTDOWN. No published information about battery placement. 09/14/21 Juco - Provide a floor plan for the house that specifies the EXACT location of the POWERWALL storage units. Label the use or purpose of the room where the units will be installed. Per a past project - Add-On Correction
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
[BATTERY JOBS]
- Provide COMPLETE installation instructions for Tesla powerwall.
- Provide floor plan for the house showing where Tesla powerwall will be located.
- Location of BATTERY cannot be in the path of travel or near a vehicle (Garage).
- Site
Must show location of rapid shutdown on the site plan.
- Roof Plan
Must show two 36" wide fire access pathways to ridgeline. (Must have both pathways, including street side pathway indicated)
Show 18" wide ventilation areas on BOTH sides of the ridge. Refer to Section R324.6.2 of the 2018 IRC.
If array covers more than 33% of the total roof area, show 36" setbacks on both sides of the ridge.
Must show location of rapid shutdown on the roof plan.
- Attachment Detail Notes
- Electrical Diagram
PV Meter between the Inverter and the Disconnect
- Electrical Diagram Notes
ALL JOBS [THE GEC / EGC WILL BE CONNECTED TO THE EXISTING GROUNDING ELECTRODE WITH AN IRREVERSIBLE CRIMP]
- Label Page
Need to label AC disconnects: EX: AC DISCONNECT (1 of 2)
Utility disconnect should state there is a 2nd disconnect located in garage if applicable. ( From Gaskin, Donnie DCR - JRivkin )
- Non Standard Planset Requirements
- Single Line Diagram
Ground mount
- Ground Mount Fencing Required
- Yes
- Ground Mount Notes
Engineering determines if ground screws are acceptable