County of Santa Cruz (AZ)
Codes
- NEC Code Version
- 2011
- Fire Code Version
- 2015 Building Code
- Code List
2012 INTERNATIONAL BUILDING CODE
2012 INTERNATIONAL RESIDENTIAL CODE
2012 INTERNATIONAL MECHANICAL CODE
2012 INTERNATIONAL PLUMBING CODE
2012 INTERNATIONAL FUEL GAS CODE
2012 INTERNATIONAL ENERGY CONSERVATION CODE
2012 INTERNATIONAL EXISTING BUILDING CODE
2012 INTERNATIONAL SWIMMING POOL AND SPA CODE
2011 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 1
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 5
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Solar Permits require stamped engineering for gravity and uplift loads. SE digital stamps on corresponding PV pages & PE Letter / Calcs. WS: 115mph. Exposure Category B. SL: 5lbs.
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,Meter Adapter,PV Breaker,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- UNSE UTILITY REQUIRES ELEVATION All plan sets submitted for approval will require an elevation view of the service and required dg equipment. Detail the height of the SES/main panel, DG (PV) meter, and the AC disconnect from the ground, and the distance between the equipment. The maximum height on equipment for Unisource customers in Mohave County is 72" and the minimum is 48" (See Elevation view Example in files section)
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Site plan to scale 1:20,1:30,1:40,1:50 Show entire parcel Must have single line diagram included
- Site
SEE SITE PLAN ATTACHMENT BELOW Site plan to scale 1:20,1:30,1:40,1:50 Show entire parcel
- Electrical Diagram
Must have single line & Three line diagram included
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
Property Setbacks noted above apply to Residential Zone 1 & 2 Property Setbacks Residential zone 3: 25' Front yard & back yard 10' Side yard Property Setbacks Residential zone 4: 20' Front yard & back yard 7' Side yard
- Setback Front Yard
- 25
- Setback Back Yard
- 25
- Setback Side Yard
- 15