City of Cypress (CA)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2025 CALIFORNIA BUILDING CODE
2025 CALIFORNIA ELECTRICAL CODE
2025 CALIFORNIA FIRE CODE
2025 CALIFORNIA PLUMBING CODE
2025 CALIFORNIA MECHANICAL CODE
2025 CALIFORNIA ENERGY CODE
2025 CALIFORNIA RESIDENTIAL CODE
2025 CALIFORNIA ADMINISTRATIVE CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Adopted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- Existing Systems,Trenching
- How Many Plansets Required
- 3
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 110
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,PV Breaker,Load Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 1
- BOS Restrictions
Standard
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
ESS disconnect required within 6ft of MSP on same wall and not blocked by walls/gates/etc
If ESS is not in line of sight of MSP an ESS disconnect required within 6ft of MSP
REMOVED ELEVATION REQUIRED DUE TO SOCAL UPDATE MEETING 11/13
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
- Cover Page Notes
Notes All Jobs
1. Contractor shall be present during all inspections.
2. A ladder shall be provided and secured to the structure at the approved roof access point per note "c" above with a Cal OSHA approved device during all inspections.
3. The roof access point requiring a ladder shall not be located over a window, door or located where it conflicts with overhead obstructions such as tree limbs, wires or signs." CRC R324.7.1.
4. Direct-Current Photovoltaic Source and Direct-Current Output circuits on or inside a building shall be contained in a metal raceway. The wiring methods shall comply with the additional installation requirements of CEC 690.31(G)(1) through (4)" CEC 690.31(G)
5. Where a UFER cannot be verified or is not present, a Grounding Electrode system shall be installed as per CEC 250.53
6. Roof-Mounted conduits and raceways shall be 7/8th's off of the roof deck or the stipulations of 310.15(B)(3)(c) shall apply.
7. Any relocated conductors in the same conduit with more than 3 conductors and more than 2 ft. in length is subject to deration.
8. Splices in the Main panel may not be done in the vertical section of the panel.
- Site
Show location of gas meter on site plan and note minimum clearance of 3 fee required to new electrical equipment.
- Site Notes
All Jobs
All interior garage wall mounted devices shall be mounted 36 above finished grade or have impact protection provided.
- Roof Plan Notes
All Jobs
1. Black module frames will be used at time of installation.
2. All tubing, wiring, etc. will be concealed as much as possible. If exposed, it will be painted to match the adjacent surface.
3. Modules will be low profile matching the house roof pitch.
- Electrical Diagram
Provide conductor count and size for all conductors being used. Derates require EE stamps on load calcs
Notes:
1. Any relocated conductors in the same conduit with more than 3 conductors and more than 2 ft. in length is subject to deration.
2. Splices in the Main panel may not be done in the vertical section of the panel.
- Electrical Diagram Notes
All Jobs
If any existing load conductors are extended more 6 feet, AFCI protection will need to be provided CEC 210.12(d).
- Label Page
Provide a permanent warning label on the main panel that states:
"WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATINGS OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACTIY OF BUSBAR' "
- Custom Placards Required
- 1
- Non Standard Revision Requirements
ALL pages with changes must be red clouded. Even if you remove something from the plans you will need to red cloud what was removed
Ground mount
- Ground Mount Fencing Required
- No