City of Hesperia (CA)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2025 CALIFORNIA BUILDING CODE
2025 CALIFORNIA ELECTRICAL CODE
2025 CALIFORNIA FIRE CODE
2025 CALIFORNIA PLUMBING CODE
2025 CALIFORNIA MECHANICAL CODE
2025 CALIFORNIA ENERGY CODE
2025 CALIFORNIA RESIDENTIAL CODE
2025 CALIFORNIA ADMINISTRATIVE CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Adopted
- Date SolarAPP+ Accepted
- 45440
- Any SolarAPP+ Restrictions
- 1
- How Many Plansets Required
- 3
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- Yes - 10kW+
- Wet Stamps Required
- None
- Structural Calculations Required
- Yes
- Ee Stamp Notes
Jobs above 10kw require EE digital stamp on TLD
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 110
- Wind Notes
Exposure Category C
- Snow Load
- 5
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,PV Breaker,Meter Adapter,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
- BOS Restrictions
Standard
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
- Please provide note, specifying 3' clearance of an ESS to a door/window
- Provide ESS labels including the nominal ESS voltage, max available short circuit from ESS.
- ESS disconnect must be within line of site of battery
AHJ MAY REQUEST FOR "Arc fault clearing time from ESS, and the date of calculations [CEC 706.7(D)]" VIA REJECTION, BUT THIS IS NOT NEEDED, UTILIZE {CEC 705.12(C) EXCEPTION} IN RESUBMITTAL LETTER TO AVOID THESE ADDED CUSTOM LABELS.
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- Yes - with dimensions
Plan set
- Attachment Detail Notes
All Jobs [LAG SCREW TO BE 3.5" IN LENGTH]
- Electrical Diagram
GMA Notes:
Bond PV neutral to PV ground inside the AC Disconnect.
Provide new ground rod in accordance with C.E.C.690(V) & 250(V)
If relocating loads, provide a Panel Schedule.
List: number, size and use of circuits.
Show the required surge protector on plans, if applicable. Centerfed 120% allowed
- Electrical Diagram Notes
Equipment grounding conductors that are not an integral part of a cable assembly shall not be smaller than 6 AWG copper or 4 AWG aluminum. [CEC 250.190(C)(1
- Custom Placards Required
- 1
Ground mount
- Ground Mount Fencing Required
- Yes
- Ground Mount Notes
- Ground Mounts require 4 sets of plans
- 10kw and above require structural Calcs
- Gm does need fence or will fail inspection GM
- setbacks 15' from front 15' rear, 5 on sides
- Codes can not reflect International - corrections will be issued for future submittals - 02/19/21
- GMs that will be a carport must have a paved approach and must be conventionally framed accessory structure with a traditional roof system such as trusses or rafters, and shingles or tiles.
- Setback Front Yard
- 15
- Setback Back Yard
- 15
- Setback Side Yard
- 5