City of Lancaster (CA)
NEC Code Version2023
Fire Code Version2018 Building Code
SolarAPP+ StatusTargeted
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2025 CALIFORNIA BUILDING CODE
2025 CALIFORNIA ELECTRICAL CODE
2025 CALIFORNIA FIRE CODE
2025 CALIFORNIA PLUMBING CODE
2025 CALIFORNIA MECHANICAL CODE
2025 CALIFORNIA ENERGY CODE
2025 CALIFORNIA RESIDENTIAL CODE
2025 CALIFORNIA ADMINISTRATIVE CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 1
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Top Right
- Date On Stamps
- Date Plans are Stamped
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 110
- Wind Notes
Exposure Category B
- Snow Load
- 20
- Snow Load Notes
N/A
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
- Batteries will require structural calculations to certify the mounting of the battery on the wall.
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- Yes
- AC Disconnect Conditional Criteria
- All power feeding the house needs to be able to be shut down within 6’ of main service panel
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Meter Adapter,Load Side Taps,Line Side Taps
- Panel Schedule Required
- Whole Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
- BOS Restrictions
AC disconnect must be on same side of fence as MSP
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
- This AHJ follows County of Los Angeles (ESS Requirements) (CA).
- Please follow this link to County of Los Angeles (ESS Requirements) (CA)
- IF USING A SUB FEED LUG KIT, VERIFY THE LUG KIT TYPE ON THE TLD (Manufacturer provided kit for the bus bar, breaker style lug connection, etc.)
- ALL Disconnects need to be located within 6’ of the main service panel
- Bollards are required if ESS is/are installed under 3' high in a driveway.
- WALL MOUNTED BATTERIES REQUIRE STRUCTURAL ENGINEERING ON BATTERY LOCATION / ATTACHMENT
- Provide calculation analysis for the ESS gravity and lateral out-of-plane support. Connection at top and bottom of stud maybe required to resist out-of-plane forces unless otherwise justified, not required. Number of fasteners, type, diameter, embedment, hardware brackets, etc. shall be clearly illustrated in detail.
- Separate ESS Disconnect Required
- Local Disconnect,ESS Disconnect
- ESS Elevation Detail Required
- Yes - with dimensions
Plan set
- Plan Set Requirements
- Please provide an equipment elevation with building disconnects identified and a corresponding disconnect schedule.
- All required means of disconnect must be located within 6 feet of the main service panel, on the same wall plane, and not separated from one another by walls, gates, fences, vegetation, or architectural features of the building.
- Site
- The layout of existing PV systems must be illustrated as individual modules, not as a single “obstruction.”
- Module layouts must be replicated in Aurora before downloading the DXF.
- Attachment Detail
All Jobs [DOUBLE FLASHING IS REQUIRED FOR THIS AHJ]
- Electrical Diagram
Existing Systems:
- Existing system and new system must be combined to have one POI in the MSP per CEC 705.12(3)(2).
- Electrical Diagram Notes
All Jobs [PER CEC 705.12(3)(2) THE BACKFEED BREAKER SHALL BE INSTALLED AT THE OPPOSITE END OF THE BUS BAR FROM THE MAIN OCPD]
- Custom Placards Required
- 1
- Placards Notes
Permanent placards in compliance with LA County Fire regulations + all permanent placards from placard page of plan set.
- Non Standard Planset Requirements
- BOS Elevation
Ground mount
- Ground Mount Fencing Required
- Yes
- Ground Mount Notes
- Ground mount: Fence must be 6-8 ft tall.
- Nuance systems are not permitted; always design using IronRidge.
- Only NRTL-listed systems are allowed in the City of Lancaster.
- If the system is not NRTL-listed, provide compliant documentation or revise the design to use traditional posts embedded in concrete footings.