City of Rancho Cordova (CA)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2025 CALIFORNIA BUILDING CODE
2025 CALIFORNIA ELECTRICAL CODE
2025 CALIFORNIA FIRE CODE
2025 CALIFORNIA PLUMBING CODE
2025 CALIFORNIA MECHANICAL CODE
2025 CALIFORNIA ENERGY CODE
2025 CALIFORNIA RESIDENTIAL CODE
2025 CALIFORNIA ADMINISTRATIVE CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Adopted
- Date SolarAPP+ Accepted
- 45076
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- Existing Systems,Trenching
- How Many Plansets Required
- 3
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- None
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 120
- Wind Notes
Exposure Category C
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,PV Breaker,Line Side Taps,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 1
Battery / ESS
- Unique Battery Placards Needed
- 1
- ESS Notes
IF REQUIRED BY SMUD: PM Required. Inv > Disco > PM > POI Between Battery and Inverter, no Disco required. Battery Specific Labels \-- Main Breaker Labeled Disconnect 1 of 2 \-- Door of Main Service Panel labeled Disconnect 1 of 2 \-- Breaker in the BU Loads Panel labeled Disconnect 2 of 2
AVOID LOCATING BATTERY IN GARAGE> ONLY IF HOMEOWNER OR SR IS GOING TO CANCEL. If battery will be placed inside interior garage.
Provide a manufacture's spec sheet and installation manual for an approved heat detector for installation in the garage that is UL and CSFM listed for installation in areas where ethe ambient temp regularly reaches over 100 f. and that is compatible to be interconnected via hardwiring with the interior smoke alarms in the dwelling.
- Heat detector -----> (Resideo wireless PROSIXHEATV)
- Smoke alarms------> (Resideo wireless PROSIXSMOKEVA)
- Control panel -------> (Resideo PORA7 or PROA7PLUS)
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Please complete the "PV Solar Checklist" from the files below. Only fill the pages relevant to the project. A quick guide to the document is below:
- Page 4 - beginning of checklist
- Page 5-11 fill for standard inverters
- Page 12-17 fill when a second standard inverter is being used
- Page 18-23 fill when microinverters are being used
- Page 24-28 fill all structural criteria
IF SOLARAPP CHECKLIST NOT REQUIERED
- Electrical Diagram
Standard
- Custom Placards Required
- 1
- Placards Notes
Permanent placards from placard page of approved plans
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim