City of Rio Vista (CA)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2025 CALIFORNIA BUILDING CODE
2025 CALIFORNIA ELECTRICAL CODE
2025 CALIFORNIA FIRE CODE
2025 CALIFORNIA PLUMBING CODE
2025 CALIFORNIA MECHANICAL CODE
2025 CALIFORNIA ENERGY CODE
2025 CALIFORNIA RESIDENTIAL CODE
2025 CALIFORNIA ADMINISTRATIVE CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Adopted
- Date SolarAPP+ Accepted
- 45195
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- Existing Systems,Trenching
- How Many Plansets Required
- 3
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Structural Calculations Required
- No
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 110
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Structural Notes
- Per Approved plans (a past project) we do not need structural.
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Meter Adapter,Line Side Taps,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
- Provide data sheets indicating the solar panels comply with UL1703 listing. Provide data sheets indicating the racking system complies with UL2703 Distribute the load using staggered mounting.
- Cover Page
Provide the following design data on the first sheet:
Occupancy group(s)/ Type(s): R-3, U.
Type(s) of construction: VB.
Fire sprinklers: Yes or No.
Number of stories and height of building.
- Site Notes
Battery [ESS/Batteries are located not less than 3 feet from doors or windows directly entering the dwelling unit. (CRC R328.4)]
- Roof Plan Notes
All Jobs [EMT shall be securely fastened in place at intervals not to exceed 10-0. In addition, each EMT run between termination points shall be securely fastened within 3-0 of each outlet box, junction box, device box, cabinet, conduit body, or other tubing termination. CEC, Sec. 358.30]
- Electrical Diagram
Standard
- Electrical Diagram Notes
Battery [ESS/Batteries are located not less than 3 feet from doors or windows directly entering the dwelling unit. (CRC R328.4)]
- Custom Placards Required
- 1
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim