City of San Leandro (CA)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2025 CALIFORNIA BUILDING CODE
2025 CALIFORNIA ELECTRICAL CODE
2025 CALIFORNIA FIRE CODE
2025 CALIFORNIA PLUMBING CODE
2025 CALIFORNIA MECHANICAL CODE
2025 CALIFORNIA ENERGY CODE
2025 CALIFORNIA RESIDENTIAL CODE
2025 CALIFORNIA ADMINISTRATIVE CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Adopted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- Existing Systems,Trenching
- How Many Plansets Required
- 3
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Top Right
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
Structural & loads
- Wind Speed
- 110
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,PV Breaker,Line Side Taps,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 1
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
ESS on exterior walls must be at least 3 ft away from doors and windows.
Please provide mounting detail of the proposed energy storage battery. Show the number and size(s) of mounting bolt and minimum embedment on the detail.
A copy of the manufacturer’s installation, operation, maintenance, and decommissioning instructions shall be provided to the owner or placed in a conspicuous location near the ESS equipment
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
**ALL JOBS:** * Need to include 2-3 photos of main panel with cover on and with the cover off. **BATTERY JOBS:** * Provide complete mounting detail of the battery and show the number and size(s) of mounting bolt and minimum embedment on the detail. CBC section 107.
- Site
**BATTERY JOBS:** * Indicate that the ESS is at least 3 ft from doors or windows * Provide a note that there will be no flammable or explosive materials near the location of the ESS.
- Roof Plan
Ensure that installation of EMT shall conform with CEC Art. 358 *
Provide complete routing of conduit from the solar zone to the point of interconnection with the electrical service. Ensure that PV conduit, wiring systems and raceway circuits are located as close as possible to the ridge or hip valley and from the hip valley as directly as possible to an outside wall to reduce trip hazards and maximize ventilation opportunities. See CRC section R324.7.3.
* Please show and specify the location of power optimizers on the plan.
- Roof Plan Notes
Ladder locations cannot be in front of windows or doors and cannot conflict with tree limbs, wires or signs. CFC 605.11.3.2.1
- Attachment Detail
* Show and specify the height of the building on the plan, coordinate the building height with submitted structural calculations (page 2).
See City of San Leandro Plan Submittal Guidelines for Solar Photovoltaic Systems. * PV modules assembly are additional loads to existing roof with specified “existing systems,” ensure that the efficiency of the existing roof can accommodate the new loads. See CAL ENERGY CODE section 110.10 (b) 4 and CRC section 324.4.1 structural requirements.
- Electrical Diagram
- 120% rule allowed per CEC 705.12(B)(2)(3)(d)
- Label Page
- Installer name and contact information label required
- Custom Placards Required
- 1
- Non Standard Revision Requirements
- Cloud and delta design changes for AHJ rejections.
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
****For plot plans/ Septic Maps**** ** ext. 213**