County of Placer (CA)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2025 CALIFORNIA BUILDING CODE
2025 CALIFORNIA ELECTRICAL CODE
2025 CALIFORNIA FIRE CODE
2025 CALIFORNIA PLUMBING CODE
2025 CALIFORNIA MECHANICAL CODE
2025 CALIFORNIA ENERGY CODE
2025 CALIFORNIA RESIDENTIAL CODE
2025 CALIFORNIA ADMINISTRATIVE CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Adopted
- Date SolarAPP+ Accepted
- 45201
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- Existing Systems,Trenching
- Revision Required
- 1
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes - Battery,Yes - Derate
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes - Battery
- Ee Stamp Notes
For derates or ESS projects: EE digital stamps required on SLD and Site Plan
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 110
- Wind Notes
Exposure Category C
- Snow Load
- 999
- Snow Load Notes
Please review this parcel map for more detailed snow loads: https://experience.arcgis.com/experience/4db2f900b53d44d092ff8d2203f91b3d/
Snow Load table: https://ecode360.com/43588343?highlight=load&highlight=loading&highlight=loads&highlight=snow&searchId=6530841256688199#43588343
ELEVATION ABOVE SEA LEVEL GROUND SNOW LOAD (Pg) (P.S.F.) SNOW DENSITY D (PCF) MAXIMUM ANTICIPATED SNOW DEPTH (Dg)
100 - 1,000 ft. 10#
1,001 - 1,600 ft. 20#
1,601 - 2,500 ft. 29#
2,501 - 3,000 ft. 55#
3,001 - 3,500 ft. 70#
3,501 - 4,000 ft. 100#
4,001 - 4,500 ft. 160#
4,501 - 5,000 ft. 200#
5,001 - 5,500 ft. 260#
5,501 - 6,000 ft. 315#
6,001 - 6,500 ft. 375#
6,501 - 7,000 ft. 430#
7,001 - 7,500 ft. 490#
7,501 ft. up 545#
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
SE required for ESS only projects.
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- Yes
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,Load Side Taps,PV Breaker,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Include this note on ELD: "Producer's storage device(s) will not cause the Host Load to exceed its normal peak demand. Normal peak demand is defined as the highest amount of power required from the Distribution System by Producer's complete facilities without the influence or use of the energy storage device(s)."
Include ESS Mounting Details
Electrical Shunt Trip/Switch shall be provided NTFPD Ordinance 02-2022 509.2.1(3) "The facility is equipped with multiple electrical sources, such as fuel cells, ESS, generators or solar photovoltaic systems. The remote main power electrical shunt trip/switch shall be hard wired to all power sources. The electrical shunt trip/switch shall be installed on the exterior of the building in an approved location protected from the elements. (A DISCONNECT TO TURN OFF THE WHOLE SYSTEM BETWEEN GATEWAY AND MSP
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Cover Page
Include Wind Speed and Ground Snow Load on Cover page Wind Speed 110MPH ELEVATION ABOVE SEA LEVEL GROUND SNOW LOAD (Pg) (P.S.F.) SNOW DENSITY D (PCF) MAXIMUM ANTICIPATED SNOW DEPTH
(Dg) 100 - 1,000 ft. †10#
1,001 - 1,600 ft. 20# 20.0
1,601 - 2,500 ft. 29# 20.0
2,501 - 3,000 ft. 55# 20.0 3.0 ft.
3,001 - 3,500 ft. 70# 20.0 3.8 ft.
3,501 - 4,000 ft. 100# 20.0 5.0 ft.
4,001 - 4,500 ft. 160# 22.7 6.5 ft.
4,501 - 5,000 ft. 200# 24.5 8.2 ft.
5,001 - 5,500 ft. 260# 26.7 9.7 ft.
5,501 - 6,000 ft. 315# 27.0 11.7 ft.
6,001 - 6,500 ft. 375# 29.6 12.7 ft.
6,501 - 7,000 ft. 430# 30.1 14.3 ft.
7,001 - 7,500 ft. 490# 30.6 16.0 ft.
7,501 ft. up 545# 32.4 16.8 ft.
- Site
- Attachment Detail
* Provide a Unirac span table, with spans highlighted for site specific design. Highlight tables for wind exposure, wind speed, snow load, roof pitch, and wind zone, as applicable.
- Electrical Diagram
120% rule allowed per CEC 705.12(B)(2)(3)(d)
- Electrical Diagram Notes
All Jobs [Further ampacity adjustments are necessary when more than 3 current carrying conductors are installed in the conduit. See CEC Table 310.15(B)(2)(a) // PER CEC 690.63 Exception: For dwelling unit, the sum of the ampere ratings of the overcurrent devices shall not exceed 120 percent of the bus bar or conductor.]
- Custom Placards Required
- 1
- Placards Notes
Placards required if equipment is behind fence.
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
6/13/24
Height Side & Rear Setback
6’ or less from natural grade 7.5’ to property line
8’ or less from natural grade 10’ to property line
15’ or less from natural grade 15’ to property line
Listed ground screws are allowed but must be confirmed with a pull or torque test, based on manufacturer recommendations and anchorage/uplift requirements of the installed system.
Engineering [When the total height from ground to top of the array (not post height) exceeds 6 feet] for mounting, attachments, and foundation to meet the minimum wind and snow loads.
Provide details of attachments, anchors, brackets, photovoltaic panels, and all hardware. Show distance from array to property lines, see attached red line drawings from AHJ and change plans.
Also please show septic and leach field. *
Include easements in the site plan *
GM arrays can not be within 50' of all easements
All waterways including streams and ponds must be included in plans and must include dimensions
Complete "Grading Permit Questionnaire" from files below and upload with PV plans.
Flood zone: 50' from ordinary high water mark.
-------------------------------------------------------------------------------------------------
Plot Map and Septic search
You can use our Online Electronic Database, link to it here: https://ecmwebprod22.placer.ca.gov/ehs2/!samples/sample-cq/index.html
Please make sure that you search our records using only the APN.
- Enter the Assessor’s Parcel Number in the field Assessor’s Parcel No. The number needs to 12 digits long and the last three digits should be 000. If you do not want to use 000 at the end of the search, you can use an * at the end of the parcel number (ex: 040-018-009-000 or 040-018-009*) Scroll down and hit Search. Do not enter the other search field options, example: addresses, dates, names, or the file will not appear. Only enter the APN with dashes and zeros.
- Please make sure that you search our records using only the APN. If you do not know the APN for the specific parcel, you can find it by using the Assessor’s GIS system, which you can locate here:
http://maps.placer.ca.gov/Html5viewer/Index.html?configBase=http://arcgis/Geocortex/Essentials/REST/sites/LIS_Public/viewers/LIS_Base-Public/virtualdirectory/Resources/Config/Default
- This will give access to all digitized records that have been published by Environmental Health.
- If there are digital records already available for the parcel in question, the files will appear under search results.
- If no records appear you can submit a Public Record Request:
https://www.placer.ca.gov/2817/Public-Records-Request
- Setback Front Yard
- 50
- Setback Side Yard
- 10