Codes
- NEC Code Version
- 2023
- Code List
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL RESIDENTIAL CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL PLUMBING CODE
2021 INTERNATIONAL FUEL GAS CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL SWIMMING POOL AND SPA CODE
2021 INTERNATIONAL FIRE CODE
2023 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- Existing Systems,Trenching,Derate
- How Many Plansets Required
- 1
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 0
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category C
- Snow Load
- 27
- Snow Load Notes
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Meter Adapter,Line Side Taps,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Location of Existing Structure(s) With Distances from Structure(s) to Front, Sides, & Rear Property Lines, and Distance to Other Existing Structure(s) &/or Proposed Structure(s) Please note on Site Plan if job is flush or ground mounted, and also note that roof mounting does not exceed angle of roof. Per Pueblo County, please use engineer scale on plans instead of architect scale. Plot plans to be drawn to an even numbered engineer scale (1 = 10', 20', 30', etc.) containing the following information on paper no larger than 11 x 17 in size (Note: Arial view maps will not be accepted.) 1. Assessor's Parcel Number2. Dimensions of the Parcel3. Easements/Building Setback Lines (if applicable)4. Address of Property5. Road Name(s)6. North Arrow7. Designated Scale8. Location AND exterior dimensions of proposed structure(s) with distances from structure(s) to front, sides, & rear property lines and distance to/separation between other existing structure(s) &/or proposed structure(s)9. Project routing sheet from the Pueblo Regional Building Department Please see attachment for Plot Plan example.
- Site
scale on site plan to engineer scale per AHJ requirements.
- Electrical Diagram
Standard
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim