County of Routt (CO)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2020 NATIONAL ELECTRICAL CODE 2018 INTERNATIONAL RESIDENTIAL CODE 2018 INTERNATIONAL FIRE CODE 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL PLUMBING CODE 2018 INTERNATIONAL MECHANICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 1
- New Planset Required For Module Swap
- 1
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Wind Loads: Building should be designed to with stain an ultimate 3-second gust of 115MPH in Routt County.
- Snow Load
- 999
- Snow Load Notes
To find snow load for particular project go to link: https://routtgis.maps.arcgis.com/apps/webappviewer/index.html?id=df84ded7ab1b4de39a9f68dd7d05a3a0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Structural Engineer Stamped Letter or Plans: Must be in accordance with specific Ground/Roof Snow Loads per location. SE digital stamps on corresponding PV pages & PE Letter / Calcs. WS: 115mph GSL : To find snow load for particular project go to link: https://routtgis.maps.arcgis.com/apps/webappviewer/index.html?id=df84ded7ab1b4de39a9f68dd7d05a3a0
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,PV Breaker,Load Side Taps,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
For City of Steamboat Springs Zone and Setback Requirements: GM cannot be located in the floodway nor can it be located within the waterbody setback, which is typically 50โ from the ordinary highwater mark.