County of Sussex (DE)
NEC Code Version2017
SolarAPP+ StatusTargeted
Wet Stamps RequiredNone
Fire Setback Enforced0
Codes
- NEC Code Version
- 2017
- Code List
2012 INTERNATIONAL BUILDING CODE
2012 INTERNATIONAL RESIDENTIAL CODE
2012 INTERNATIONAL ENERGY CONSERVATION CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- Other (See Submission Notes)
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- None
- Structural Calculations Required
- No
Fire setbacks
- Fire Setback Enforced
- 0
- Setback Notes
* 12/22/2020 - Confirmed setbacks are not enforced - NH
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 20
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
- THIS AHJ DOES NOT NEED STRUCTURAL LETTER OR STAMPED PLANS FOR REVIEW
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates,All Jobs
- Allowed POI
- Meter Adapter,Load Side Taps,PV Breaker,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Electrical load calcs required for ALL projects. (even for MPU)
- Electrical Diagram
Additional disconnect needed at the MSP when the MSP is interior
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- No