City of Largo (FL)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2023 8TH EDITION FLORIDA BUILDING CODE: BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL
2023 8TH EDITION FLORIDA BUILDING CODE: MECHANICAL
2023 8TH EDITION FLORIDA BUILDING CODE: PLUMBING
2023 8TH EDITION FLORIDA BUILDING CODE: FUEL GAS
2023 8TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION
2023 8TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY
2023 8TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA)
2020 NATIONAL ELECTRIC CODE (NEC)
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 2
- Revision Required
- 1
- Rough Inspection
- Rough Electrical
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
Digitally Verified Signature
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 145
- Wind Notes
Exposure Category C ; HVHZ
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Structural Notes
SE & EE digital stamps on all PV pages, FL statute, PE Letter & Calcs. WS 145 MPH
Digitally Verified Signature
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,Line Side Taps,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
ESS shall only be installed in the following locations:
(1) In attached garages separated from the dwelling unit living area and sleeping units in accordance with the local building code
(2) In detached garages and detached accessory structures
(3) Outdoors on exterior walls or on the ground located a minimum of 3 ft (914 mm) from doors and windows
(4) In enclosed utility closets and storage or utility spaces. [NFPA 855 (2020):15.6.1] Shall detail the locations of all doors and windows for verification of compliance with the aforementioned code.
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Roof Plan
Wind speed must be listed on plans.
- Roof Plan Notes
Layout subject to change.
- Electrical Diagram Notes
Interconnection Method subject to change
- Custom Placards Required
- 1
- Placards Notes
TECO Placard
- Required when the utility provider is Tampa Electric Company (TECO).
- Warehouse orders and keeps these placards in stock.
Custom Placards (6x8)
- Order 2 placards from:
- Email the current site plan (Site Placard Sheet) to the vendor when placing the order.
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
- AHJ has request concrete footers
- utilize iron ridge with this AHJ