City of Lauderdale Lakes (FL)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2023 8TH EDITION FLORIDA BUILDING CODE: BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL
2023 8TH EDITION FLORIDA BUILDING CODE: MECHANICAL
2023 8TH EDITION FLORIDA BUILDING CODE: PLUMBING
2023 8TH EDITION FLORIDA BUILDING CODE: FUEL GAS
2023 8TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION
2023 8TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY
2023 8TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA)
2020 NATIONAL ELECTRIC CODE (NEC)
- ASCE Code Specification
- ASCE 7-22
SolarAPP+ & submittal
- How Many Plansets Required
- 2
- Revision Required
- 0
- Rough Inspection
- Rough Electrical
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Wet Structural,Wet Electrical
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 170
- Wind Notes
Exposure Category C HVHZ
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
- Hand-written signature required with raised seal.
- SIF Form required
- Provide wind load pressure site an calculated, zones, show a legend and show zone on roof plan. Wind load 170 MPH Broward county.
- Anchoring system ,provide and NOA or Florida product approval.
- Provide for flashing and for seal at anchors- truss NOA or Florida product approval.
- All plans submitted embossed or wet stamp ORIGINAL SIGNATURE NO COPIES
- Provide calculations based on the FBC 2020 chapter 16, Broward county 170 MPH, HVHZ
- If engineers must be changed during the project, complete the hold harmless form in the files below
- This AHJ does not accept stamped signature. Signature required
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- All Jobs
- Allowed POI
- Load Side Taps,PV Breaker,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Module must be 5,000PA wind rated.
New stock of CS3N-400MS so utilize these for new projects - MVS 11-11-2024
For Enfin Finance, use Qcell 405-TS modules to fulfill the HVHZ requirements.
ATTACH IF CHEM CURB -----> ATTACHMENT
ATTACH SIF (SEE FILES)
- Site
-Must call out 2 roof access points, in the front of the house
- Roof Plan
- Framing to be included on roof plan.
- Attachments and rail also (not for Infinity)
- Roof Zones to be added to plans, typically 3 ft around the whole home, see Roof Zone Document in file section
- Roof Plan Notes
All Jobs [Wind Speed: 170MPH]
- Attachment Detail
- Do not use rail less
- Comp Shingle - Unirac Flashkit Pro (spec sheet is named 2021 NOA Unirac in file section below, add to plans)
- Tile - Snap'n'Rack Tile Hook (spec sheet is named NOA SnapNrack in file section below, add to plans)
- The go to sealant that needs to be used here is M1.
- Include spec sheet and NOA into the plans as required by the AHJ
- Electrical Diagram
label service entrance conductors and meter can rating
- Electrical Diagram Notes
All Jobs [Inverter equipped with rapid shutdown per NFPA 70 - Section 690.12]
- Label Page
FLORIDA - 2020 NFPA1:11 CAD BLOCK
- Label Page Notes
- On the plaque or directory, provide the wording CAUTION: MULTIPLE SOURCES OF POWER; per 11.12.2.1.4.5.
- For the plaque or directory, posted diagrams shall be correctly oriented with respect to the diagram's location; if posted on the north side of the building, north should be oriented to the bottom, per 11.12.2.1.4.6 and NFPA 70 - Article 705.10.
- Custom Placards Required
- 1
- Placards Notes
- Site map on 6x6 red placard with white lettering, address on the bottom above "Photovoltaic system equipped with rapid shutdown"
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim