City of Pinellas Park (FL)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2023 8TH EDITION FLORIDA BUILDING CODE: BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL
2023 8TH EDITION FLORIDA BUILDING CODE: MECHANICAL
2023 8TH EDITION FLORIDA BUILDING CODE: PLUMBING
2023 8TH EDITION FLORIDA BUILDING CODE: FUEL GAS
2023 8TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION
2023 8TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY
2023 8TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA)
2020 NATIONAL ELECTRIC CODE (NEC)
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
Digitally Verified Signature
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
36" FIRE ACCESS PATH REQUIRED ON BOTH SIDES OF RIDGE. NOT FEWER THAN 2 PATHWAYS REQUIRED ON SEPARATE ROOF PLANES FROM LOWEST ROOF EDGE TO RIDGE AND NOT LESS THAN 36" WIDE, SHALL BE PROVIDED ON ALL BUILDINGS. FBC R324.6.1
Structural & loads
- Wind Speed
- 150
- Wind Notes
Exposure Category C ; HVHZ
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Structural Notes
SE & EE digital stamps on all PV pages, FL Statute, PE Letter & Calcs. WS 150 MPH Provide u builder cantilever (from engineering report) (a past project DCR) 12/22/20 JM - Max allowable span and max allowable cantilever must be listed on plans
Digitally Verified Signature
"Regarding RAIL overhang, PANEL CANTILEVER in a portrait or landscape layout format. If the Engineer regards these installations as synonymous, A sealed Engineer’s letter stating so."
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,PV Breaker,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Wind speed needs to be added onto plans,
- Roof Plan
Fire setbacks are enforced.
- Roof Plan Notes
Layout subject to change.
- Attachment Detail
* Provide u builder cantilever (from engineering report) * The max rail overhang in the array installation table must default to 24
- Electrical Diagram Notes
Interconnection Method subject to change
- Custom Placards Required
- 1
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim