County of Charlotte (FL)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2023 8TH EDITION FLORIDA BUILDING CODE: BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL
2023 8TH EDITION FLORIDA BUILDING CODE: MECHANICAL
2023 8TH EDITION FLORIDA BUILDING CODE: PLUMBING
2023 8TH EDITION FLORIDA BUILDING CODE: FUEL GAS
2023 8TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION
2023 8TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY
2023 8TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA)
2020 NATIONAL ELECTRIC CODE (NEC)
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 2
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
FL statute letter required
Digitally Verified Signature
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 160
- Wind Notes
ATC Hazards by Location (atcouncil.org)
Use above site to search address
Under the section marked ASCE 7-16
Use MPH from Risk Category II
Exposure C
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Structural Notes
DO NOT SEPARATE THE PAGES.
Stamped planset in one PDF file
Combined Planset needs to be fully stamped.
Digitally Verified Signature
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,PV Breaker,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Service Ground Requirements
- Supply Tap Neutral Ground Bond Required
- 1
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- No
- ESS Elevation Detail Required
- No
Plan set
- Cover Page
- Cover Page Notes
All Jobs [THIS SYSTEM DESIGNED WITH: // WIND SPEED: 160 // RISK CATEGORY II // WIND EXPOSURE: C]
- Roof Plan Notes
All Jobs [Layout subject to change]
- Electrical Diagram
RELOCATION OF ANY LOAD REQUIRES PANEL SCHEDULE
LINE SIDE TAP REQUIRE N-G BOND IN DISCO
Line side tap EGC must be separate and outside of enclosure. utilize Florida tap blocks
MUST REFLECT THIS ON EACH AND EVERY PROJECT: (This will be job specific. Note below will be added to every SLD and must be edited when appropriate)
Must reflect either-or [free air vs conduit]
#6 AWG IN FREE AIR OR #10 AWG MUST BE IN EMT CONDUIT
Note:
All Jobs [Ground to be installed and run through conduit from modules to the disconnect - after that the ground will be ran free air to the end point for the ground unless otherwise specified]
- Electrical Diagram Notes
All Jobs [Interconnection Method subject to change]
- Label Page
- Label Page Notes
- Custom Placards Required
- 0
- Non Standard Revision Requirements
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
AHJ confirmed that the required setbacks are 40' from front 20' from side and 20' from rear. JM
- Setback Front Yard
- 40
- Setback Back Yard
- 20
- Setback Side Yard
- 20