County of Citrus (FL)

Florida Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2020
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural,Digital Electrical
Fire Setback Enforced1

Codes

NEC Code Version
2020
Fire Code Version
2018 Building Code
Code List

2023 8TH EDITION FLORIDA BUILDING CODE: BUILDING

2023 8TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL

2023 8TH EDITION FLORIDA BUILDING CODE: MECHANICAL

2023 8TH EDITION FLORIDA BUILDING CODE: PLUMBING

2023 8TH EDITION FLORIDA BUILDING CODE: FUEL GAS

2023 8TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION

2023 8TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING

2023 8TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY

2023 8TH EDITION FLORIDA FIRE PREVENTION CODE

2020 NATIONAL ELECTRIC CODE

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

How Many Plansets Required
Other (See Submission Notes)
Revision Required
1
Rough Inspection
None
New Planset Required For Module Swap
0

Stamps

Ee Stamp Required On SLD
Yes
Wet Stamps Required
Digital Structural,Digital Electrical
Structural Calculations Required
Yes
Ee Stamp Notes

FL Statute letter required


Digitally Verified Signature

Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
1
Ridge Setback
18
Setback Notes

AHJ requests 18" setbacks to be shown around thermal piping (if shown on plans)

Structural & loads

Wind Speed
135
Wind Notes

Exposure Category C

Always check ASCE HAZARDS for the correct windspeed under ASCE 7-22

Snow Load
0
Reducible Snow Load Allowed
1
Max Attachment Spacing
48
Structural Notes

Digitally Verified Signature

Minimum Ground On Roof
#10

Electrical

Electrical Load Calcs Required
Derates
Allowed POI
PV Breaker,Line Side Taps,Load Side Taps
Panel Schedule Required
Partial Home Backup
Service Ground Requirements

Do not install Grounding Electrode conductor in the same raceway as feeders and Grounded conductors. Run a separate GEC from the PV service disconnect to the existing GEC

Temperature Rating
90
De Rating Ampacity
0.96

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

AHJ needs load calculation of the interior panel if we are backing up 100% of that panel


1/5/23 battery projects, we need to isolate all Generation on site with a single Disconnect

Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Label Page

FLORIDA 2020 CAD BLOCK

Custom Placards Required
0

Ground mount

Ground Mount Fencing Required
No
Ground Mount Notes

Unable to determine exact setbacks per property type in County of Citrus.


Use this (Citrus County Geographic Information Systems (GIS) - Address Lookup) website to lookup the address and get the setbacks for Main Structures to use them as reference for Ground Mount array (Accessory Building)

Compiled from public records, 2026. Requirements change with code cycles and local amendments. Verify with the County of Citrus (FL) building department before you rely on this, and treat it as a research head start, not a ruling. Getting quotes? Run them through the quote checker first.