County of Manatee (FL)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2023 8TH EDITION FLORIDA BUILDING CODE: BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL
2023 8TH EDITION FLORIDA BUILDING CODE: MECHANICAL
2023 8TH EDITION FLORIDA BUILDING CODE: PLUMBING
2023 8TH EDITION FLORIDA BUILDING CODE: FUEL GAS
2023 8TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION
2023 8TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY
2023 8TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA)
2020 NATIONAL ELECTRIC CODE (NEC)
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- Revision Required
- 1
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
Digital stamps on all PV pages 1-7a. Verifiable digital signatures on all stamps.
This text needs to show on all digital stamps, "Printed copies of this document are not considered signed and sealed and the signatures must be verified on any electronic copies."
ONLY stamps verified by 3rd party such as DigiCert, IdenTrust, GlobalSign, Entrust, Symantec(owned by Digicert) and Notarius. NOT ACCEPTED are Adobe/DocuSign/or SealPact.
Digitally Verified Signature
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 150
- Wind Notes
Exposure Category C
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Structural Notes
Digital stamps on all PV pages 1-7a. Verifiable digital signatures on all stamps.
Manual Stamping required:
This text needs to show on all digital stamps, "Printed copies of this document are not considered signed and sealed and the signatures must be verified on any electronic copies."
ONLY stamps verified by 3rd party such as DigiCert, IdenTrust, GlobalSign, Entrust, Symantec(owned by Digicert) and Notarius. NOT ACCEPTED are Adobe/DocuSign/or SealPact.
Digitally Verified Signature
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,PV Breaker,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- ESS Elevation Detail Required
- No
Plan set
- Roof Plan
Include the attachment locations for the racking system overlayed with the modules on the roof plan - MUST SHOW ATTACHMENTS ON PLANSET (Including rafters)
- Roof Plan Notes
All Jobs [Layout subject to change]
- Electrical Diagram
SHOW SPD ON SLD
- Electrical Diagram Notes
All Jobs [Interconnection Method subject to change]
- Label Page
FLORIDA 2020 CAD BLOCK
- Custom Placards Required
- 1
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim