County of Liberty (GA)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2023 NATIONAL ELECTRICAL CODE
2018 INTERNATIONAL BUILDING CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 1
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Top Right
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 130
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- All Jobs
- Allowed POI
- Load Side Taps,Line Side Taps,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- No
- ESS Elevation Detail Required
- No
Plan set
- Electrical Diagram
Centerfed 120%: EE Stamp Required
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
**REQUIRES SEPARATE ZONING PERMIT** No gravel base needed. No height restrictions. No minimum freeze depth. Between 3-15 acres: 15' Front, Side, and Back. 20' from public right of way. Small scale solar energy systems - Occupies less than three (3) acres. 3 acres setback requirements: 25' Front, Side, and Back if within 100' of residential zone or public right of way. Intermediate scale solar energy systems - Occupies three (3) to fifteen (15) acres. The intermediate scale SES shall be located no closer than the lesser of (a) fifteen (15) feet from any property line or easement, or (b) the setback standards for the underlying zoning district, if any; The intermediate scale SES shall be located no closer than the lesser of (a) twenty (20) feet from any public right-of-way, or (b) the setback standards for the underlying zoning district, if any; and The intermediate scale SES shall be located no closer than 50 feet from any residential dwelling unit. Large scale solar energy systems - Occupies more than fifteen (15) acres. The large scale SES shall be located no closer than the lesser of (a) fifteen (15) feet from any property line or easement, or (b) the setback standards for the underlying zoning district, if any; The large scale SES shall be located no closer than the lesser of (a) twenty (20) feet from any public right-of-way, or (b) the setback standards for the underlying zoning district, if any; and The large scale SES shall be located no closer than 100 feet from any residential dwelling unit.