City of Collinsville (IL)
NEC Code Version2020
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural,Digital Electrical
Fire Setback Enforced1
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2021 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL FIRE CODE 2021 INTERNATIONAL PROPERTY MAINTENANCE CODE
2021 INTERNATIONAL RESIDENTIAL CODE
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2020 NATIONAL ELECTRICAL CODE
2012 NFPA 101 LINE SAFETY CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 1
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Ridge Setback
- 3
- Rake Setback
- 3
- Setback Notes
follow IFC 2018 setbacks
Structural & loads
- Wind Speed
- 107
- Snow Load
- 23
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,PV Breaker,Meter Adapter,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
- BOS Restrictions
- From AHJ: "No line side taps allowed. Upgrade meter base with a Milbank U6281XL125 with an Eaton BRSF125 sub-feed lug for line-side tap."
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
- Provide the type of connector for the line-side tap and the manufacturer’s specs.
- Roof Plan
- Use Roof Access Point verbiage on the plans (not pathways).
- Custom Placards Required
- 1
- Placards Notes
- Need custom site map placard for ALL projects.
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim