City of Saint Charles (IL)

Illinois Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2020
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1

Codes

NEC Code Version
2020
Fire Code Version
2018 Building Code
Code List

2021 INTERNATIONAL BUILDING CODE

2021 INTERNATIONAL RESIDENTIAL CODE

INTERNATIONAL FIRE CODE

2018 ILLINOIS ENERGY CODE INTERNATIONAL SOLAR ENERGY PROVISIONS CODE ST CHARLES MUNICIPAL CODE SECTION 13.08.315 & 13.08.320

2020 NATIONAL ELECTRICAL CODE W/ ST. CHARLES AMENDMENTS

IEBC Accepted
1
ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

How Many Plansets Required
3
Revision Required
0
New Planset Required For Module Swap
0

Stamps

Ee Stamp Required On SLD
No
Wet Stamps Required
Digital Structural
Structural Calculations Required
Yes
Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
1
Setback Notes

Standard

Structural & loads

Wind Speed
90
Wind Notes

Exposure Category B

Snow Load
30
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Structural Notes

Standard

Minimum Ground On Roof
#10

Electrical

AC Disconnect Required
No
Electrical Load Calcs Required
Derates
Allowed POI
Line Side Taps,Meter Adapter,PV Breaker,Load Side Taps
Panel Schedule Required
Partial Home Backup
Temperature Rating
75
De Rating Ampacity
1

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Standard

Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Electrical Diagram

EMT not allowed.


LINE SIDE TAP NOT ALLOWED.


POI MUST BE A BREAKER INSIDE THE MSP (INSIDE HOME)

#6 EGC from mods to inverter Wire Ampacity - do not use 90 degree ratings, use 75 degree (per staff)

Show DC conductors on the wire calculation table

Informational note: Customer must have meter/main outside and MB inside MSP (disconnects outside and inside) otherwise upgrade will be required. (per staff)

Electrical Diagram Notes

Conduit mounted 2" off of roof using Unirac Conduit mount

Custom Placards Required
0

Ground mount

Ground Mount Fencing Required
Mesh/Scrim
Ground Mount Notes
  • 10' Setback from house (principal structure) Cannot be taller than 20'
  • Design review is needed if located in RT, BL, BC, OR, CBD-1 and CBD-2 zoning districts (call city to check)
  • Cannot be located within an easement
Compiled from public records, 2026. Requirements change with code cycles and local amendments. Verify with the City of Saint Charles (IL) building department before you rely on this, and treat it as a research head start, not a ruling. Getting quotes? Run them through the quote checker first.