County of Tazewell (IL)
NEC Code Version2017
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1
Codes
- NEC Code Version
- 2017
- Fire Code Version
- 2018 Building Code
- Code List
2018 International Residential Building Code
2018 International Building Code
2018 International Existing Building Code
2018 International Property Maintenance Code
2017 National Electrical Code Edition
2018 International Mechanical Code
2018 International Fire Code Illinois Energy Conservation Code
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 1
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 110
- Snow Load
- 999
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
SE required unless the modules are on a detached structure. PE calcs must reference 2018 NDS
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- Yes
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Load Side Taps,Line Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
- BOS Restrictions
AC DISCONNECT WITHIN 10FT OF UTILITY METER PV RAPID SHUT DOWN COMPLIES WITH ASM 1500.01(6), ASM 1500.02(6), AND ASM 1500.01(8)
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
AHJ requirement - Total weight of modules and rails must be on planset
- Roof Plan
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
- Show total array area on plans
- Show distance from Ground mount array to main street in front of home/residence
- AHJ database as each area of the County of Tazewell has different setbacks. GM PM confirmed this with AHJ.
- Septic tank always needs to be on plans unless home is on sewer. If we do not have septic tank information, try calling the County's Health Department to see if they have it on file.
- Setback Front Yard
- 50
- Setback Back Yard
- 5
- Setback Side Yard
- 5