Village of Addison (IL)
Codes
- NEC Code Version
- 2017
- Fire Code Version
- 2018 Building Code
- Code List
2018 INTERNATIONAL BUILDING CODE (IBC)
2018 INTERNATIONAL RESIDENTIAL CODE (IRC)
2018 INTERNATIONAL MECHANICAL CODE (IMC)
2018 INTERNATIONAL PLUMBING CODE (IPC)
2018 INTERNATIONAL FUEL GAS CODE (IFGC)
2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC)
2018 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC)
2017 NATIONAL ELECTRICAL CODE (NEC)
AS ADOPTED BY VILLAGE OF ADDISON
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Not accepted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 3
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 1
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 110
- Wind Notes
Exposure Category B
- Snow Load
- 30
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Load Side Taps,Line Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 1
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Electrical Diagram
MPU Include type of service (overhead or underground) Show amperage, voltage, and location of new proposed panel along with any required working clearances Include panel schedule showing the number and the size of circuits Include the size and type of conduit used show the method of grounding the system For Overhead services, also include: Clearance of service drop conductor above the roof (if applicable) Clearance of service drop conductors above grade Verification that the service head will be located above the point of attachment Other MPU notes Dwelling units exceeding 2,000 sq feet shall be supplied with a minimum 200A single phase, three wire panel RMC shall be used as the raceway for service entrance conductors from the meter socket to the main disconnect
- Electrical Diagram Notes
**When MPU is needed please provide the following on planset :** * Indicate that smoke detectors will be provided. Due to the electrical panel upgrade smoke alarms must be provided. * Indicate that smoke alarms will be provided within each bedroom in the immediate vicinity but outside of each bedroom and on each level of the home. * All smoke alarms must be hard wired, with back up batteries and wired in such a way that the activation of any one detector will sounds all detectors. * Wireless alarms can be used. Also provide a carbon monoxide detector within 15 feet of every room used for sleeping.
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim