Village of Elk Grove Village (IL)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2015 Building Code
- Code List
2024 INTERNATIONAL RESIDENTIAL CODE
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL MECHANICAL CODE
2018 INTERNATIONAL PLUMBING CODE
2023 NATIONAL ELECTRICAL CODE
2014 ILLINOIS PLUMBING CODE
2018 INTERNATIONAL FUEL GAS CODE
2018 INTERNATIONAL ENERGY CONSERVATION CODE
2018 INTERNATIONAL PROPERTY MAINTENANCE CODE
2024 INTERNATIONAL FIRE CODE 2018 ILLINOIS ACCESSIBILITY CODE
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- Revision Required
- 1
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 30
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,Load Side Taps,Meter Adapter,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 1
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Electrical Diagram
MPU:
- Requires exterior disconnect and panel surge protector
- Aluminum feeders must be removed and replaced with copper
- Ground and bond the service per the 2023 NEC
- Raceway to be IMC or rigid, and upturns to be IMC or rigid per 2023 NEC as amended by EGV.
- •Emergency disconnects shall be one of the following: (1) Emergency Disconnect, Service Disconnect (2) Other listed disconnect switches or circuit breakers on the supply side of each service disconnect that are suitable for use as service equipment shall be marked “Emergency Disconnect, Not Service Equipment.”
- Electrical Diagram Notes
MPU [Carbon monoxide and smoke detectors throughout the house are required to be in compliance with the 2018 IRC as amended by EGV (one on each floor, one in each bedroom - minimum of 36” away from tip of fan blade, and one within 15’ outside of bedrooms). // One hardwired detector shall be installed in the vicinity of the work and all other detectors can battery powered. // All devices shall be interconnected]
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim