City of Wichita / County of Sedgwick (KS)
NEC Code Version2023
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Electrical,Digital Structural
Fire Setback Enforced1
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2024 INTERNATIONAL BUILDING CODE
2024 INTERNATIONAL EXISTING BUILDING CODE
2024 INTERNATIONAL MECHANICAL CODE
2024 INTERNATIONAL FUEL GAS CODE
2024 INTERNATIONAL FIRE CODE
2024 INTERNATIONAL RESIDENTIAL CODE
2024 INTERNATIONAL ENERGY CONSERVATION CODE
2024 INTERNATIONAL PROPERTY MAINTENCE CODE
2023 NATIONAL ELECTRICAL CODE
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Electrical,Digital Structural
- Structural Calculations Required
- Yes
- Ee Stamp Notes
Standard
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Date Plans are Stamped
Fire setbacks
- Fire Setback Enforced
- 1
Structural & loads
- Wind Speed
- 110
- Wind Notes
https://ascehazardtool.org/
- Snow Load
- 15
- Snow Load Notes
https://ascehazardtool.org/
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
PE Letter and Calcs
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- No
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,PV Breaker,Load Side Taps,Meter Adapter
- Supply Tap Neutral Ground Bond Required
- 1
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
- BOS Restrictions
Standard
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard ESS Requirements
- Separate ESS Disconnect Required
- No
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
For manufactured mounting systems, provide the following information about the mounting system:
- a) Mounting System Manufacturer ______
- b) Product name and Model Number ______
- c) Total Weight of Solar Electric Modules and Rails _______________lbs.
- d) Total Number of Attachment Points_______________________
- e) Weight per Attachment Point (c ÷ d) ______________________lbs.
- f) Maximum Spacing between Attachment Points on a Rail _________________inches.
- g) Total Surface Area of Solar Electric Modules (square feet) _______________ft²
- h) Distributed Weight of Solar Electric Module on Roof (c ÷ g) ______________lbs./ft²
- Cover Page
Standard
- Site
Standard
- Roof Plan
Standard
- Attachment Detail
Standard
- Electrical Diagram
All hotbus panels require adding an MBE on the exterior of the home.
Line Side Taps needs to be within 10' of the meter.
- Label Page
Standard
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
Standard Ground Mount requirements
- Setback Front Yard
- 10
- Setback Back Yard
- 5
- Setback Side Yard
- 5