City of St. John (MO)
NEC Code Version2014
Fire Code Version2015 Building Code
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1
Codes
- NEC Code Version
- 2014
- Fire Code Version
- 2015 Building Code
- Code List
2015 International Residential Code (IRC)
2015 International Building Code (IBC)
2014 National Electrical Code(NEC)
2015 International Fire Code (IFC)
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 1
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Date Plans are Stamped
Fire setbacks
- Fire Setback Enforced
- 1
Structural & loads
- Wind Speed
- 115
- Wind Notes
https://ascehazardtool.org/
Wind speed is 115mph or 89 with allowable stress design
- Snow Load
- 20
- Snow Load Notes
https://ascehazardtool.org/
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- No
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,PV Breaker,Line Side Taps,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Supply Tap Neutral Ground Bond Required
- 1
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
- BOS Restrictions
Standard
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard ESS Requirements
- Separate ESS Disconnect Required
- No
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
- Provide specs showing inverts are in accordance with UL 1741
- Provide specs showing mods and racking are in accordance with UL 1703
- Cover Page
Standard
- Site
- Note the names of street(s) that adjoin the lot, the lot number, and the subdivision name
- Roof Plan
- Dimension the roof length and width
- Show the dimensions of the array(s). Add dimensions from edges of array(s) to roof edges and to other arrays
- Attachment Detail
Standard
- Electrical Diagram
Standard
- Label Page
Standard
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
- Standard Ground Mount requirementsNote the names of street(s) that adjoin the lot, the lot number, and the subdivision name
- Label all existing features/structures on the lot including septic and wells.
- Dimension an area free of brush that extends a minimum of 10ft from each side of the array
- Show with arrows water run off direction(s) and show and label existing swales. The location (s) of the solar PV array system structure shall not obstruct swales or run-off
- Show, label, and dimension pier locations and their on center spacing. Show and note pier and pier flare diameters and their required depth below grade
- Setback Front Yard
- 10
- Setback Back Yard
- 5
- Setback Side Yard
- 5