County of St. Louis (MO)
NEC Code Version2014
Fire Code Version2015 Building Code
SolarAPP+ StatusTargeted
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1
Codes
- NEC Code Version
- 2014
- Fire Code Version
- 2015 Building Code
- Code List
2015 INTERNATIONAL RESIDENTIAL CODE (IRC)
2015 INTERNATIONAL BUILDING CODE (IBC)
2014 NATIONAL ELECTRICAL CODE (NEC)
2015 INTERNATIONAL FIRE CODE (IFC)
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- Revision Required
- 1
- Rough Inspection
- Footing inspection
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Date Plans are Stamped
Fire setbacks
- Fire Setback Enforced
- 1
Structural & loads
- Wind Speed
- 115
- Wind Notes
- Wind speed is 115mph or 89 with allowable stress design.
- Snow Load
- 20
- Reducible Snow Load Allowed
- 1
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,Line Side Taps,PV Breaker,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
- BOS Restrictions
Taps may not be located in the Main Service Panel unless it is approved for the connection of multiple power sources. A Junction Tap Box may be used in lieu of the MSP for housing the taps.
Battery / ESS
- Unique Battery Placards Needed
- 0
- Separate ESS Disconnect Required
- No
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
- Provide specs showing inverts are in accordance with UL 1741
- Provide specs showing mods and racking are in accordance with UL 1703
- Provide UL listing if tapping inside panel, if this cannot be provided, tap outside in tap box
- Cover Page
- Site
- Note the names of street(s) that adjoin the lot, the lot number, and the subdivision name
- Roof Plan
- Dimension the roof length and width
- Show the dimensions of the array(s). Add dimensions from edges of array(s) to roof edges and to other arrays
- Custom Placards Required
- 0
- Non Standard Revision Requirements
- For revisions only submit the revised pages with a narrative letter describing the changes page by page.
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
- Note the names of street(s) that adjoin the lot, the lot number, and the subdivision name
- Label all existing features/structures on the lot including septic and wells.
- Dimension an area free of brush that extends a minimum of 10ft from each side of the array
- Show with arrows water run off direction(s) and show and label existing swales. The location (s) of the solar PV array system structure shall not obstruct swales or run-off
- Show, label, and dimension pier locations and their on center spacing. Show and note pier and pier flare diameters and their required depth below grade
- Setback Front Yard
- 10
- Setback Back Yard
- 5
- Setback Side Yard
- 5