City of Great Falls (MT)

Montana Authority Having Jurisdiction Solar permitting requirements

Spot something wrong?

These change with code cycles. If a requirement here is out of date or missing, tell us and we'll fix it.

Report a correction
NEC Code Version2020
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural
Fire Setback EnforcedYes

Codes

NEC Code Version
2020
Fire Code Version
2018 Building Code
Code List

2021 INTERNATIONAL BUILDING CODE

2021 INTERNATIONAL EXISTING BUILDING CODE

2020 NATIONAL ELECTRICAL CODE

IEBC Accepted
Yes
ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

Revision Required
No
New Planset Required For Module Swap
No

Stamps

Ee Stamp Required On SLD
No
Wet Stamps Required
Digital Structural
Structural Calculations Required
Yes
Stamp Location On Plans
N/A
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
Yes

Structural & loads

Wind Speed
999
Wind Notes

https://ascehazardtool.org/

see attachement

Snow Load
40
Snow Load Notes


Reducible Snow Load Allowed
No
Max Attachment Spacing
96
Structural Notes

Must be Stamped by Licensed MT Engineer

calcs must show seismic load B

Minimum Ground On Roof
#10

Electrical

AC Disconnect Required
No
Electrical Load Calcs Required
Derates
Allowed POI
Load Side Taps,PV Breaker,Meter Adapter,Line Side Taps
Supply Tap Neutral Ground Bond Required
Yes
Temperature Rating
90
De Rating Ampacity
0.91
BOS Restrictions

Standard - disco on each structure required

Battery / ESS

Unique Battery Placards Needed
No
ESS Notes

Standard ESS Requirements

Separate ESS Disconnect Required
No
ESS Elevation Detail Required
No

Plan set

Plan Set Requirements

Standard

Cover Page

Standard


Site

Standard

Roof Plan

Standard

Attachment Detail

"To ensure the pv systems can withstand the strong winds in Great Falls, please include an extra clip / attachment point on the end of the rail, followed by the 48” on-center attachment for the clips."


Please.pdf" in the files section for an example.

Electrical Diagram

Standard

Label Page

MONTANA label drop down

Custom Placards Required
No

Ground mount

Ground Mount Fencing Required
No
Ground Mount Notes

Standard Ground Mount requirements

Setback Front Yard
10
Setback Back Yard
5
Setback Side Yard
5
Compiled from public records, 2026. Requirements change with code cycles and local amendments. Verify with the City of Great Falls (MT) building department before you rely on this, and treat it as a research head start, not a ruling. Getting quotes? Run them through the quote checker first.