City of Pleasantville (Atlantic County) (NJ)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2021 INTERNATIONAL BUILDING CODE NJ EDITION
2021 INTERNATIONAL RESIDENTIAL CODE NJ EDITION
2021 INTERNATIONAL FIRE CODE NJ EDITION
2021 INTERNATIONAL ENERGY CONSERVATION CODE NJ EDITION
2021 INTERNATIONAL EXISTING BUILDING CODE NJ EDITION
2021 INTERNATIONAL FUEL GAS CODE NJ EDITION
2021 INTERNATIONAL MECHANICAL CODE NJ EDITION
2021 INTERNATIONAL PLUMBING CODE NJ EDITION
2020 NATIONAL ELECTRICAL CODE NJ EDITION
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 2
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Wet Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 122
- Wind Notes
Exposure Category B
- Snow Load
- 20
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
**Raised seal required for (2) plans.** SE raised seal stamps on corresponding PV pages & PE Letter / Calcs. WS: 122mph. Exposure Category B. SL: 20lbs. Send 2 copies 201 Commerce Dr Ste. 5 Moorestown, NJ 08057 2018 NJ International Building Code must be shown on Engineering
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,Load Side Taps,Meter Adapter,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
- BOS Restrictions
We need to show all line side connections in a tap box.
No piercing connection in this township
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- No
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Electrical load calcs required for ALL projects. (even for MPU)
- Electrical Diagram
If lineside tap (LST), then a Hoffman Tap Box (junction box) is required.
- Electrical Diagram Notes
- Custom Placards Required
- 1
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim