City of Hobbs (NM)
NEC Code Version2020
SolarAPP+ StatusTargeted
Wet Stamps RequiredDigital Structural,Digital Electrical
Fire Setback Enforced0
Codes
- NEC Code Version
- 2020
- Code List
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL RESIDENTIAL CODE
2021 INTERNATIONAL FIRE CODE
2021 NEW MEXICO COMMERCIAL ENERGY CONSERVATION CODE
2021 NEW MEXICO RESIDENTIAL ENERGY CONSERVATION CODE
2021 NEW MEXICO RESIDENTIAL BUILDING CODE
2021 NEW MEXICO EXISTING BUILDING CODE
2021 NEW MEXICO HISTORIC EARTHEN BUILDINGS CODE
2021 NEW MEXICO UNIFORM MECHANICAL CODE
2021 NEW MEXICO EARTHEN BUILDING MATERIALS CODE
2021 UNIFORM PLUMBING CODE
2012 UNIFORM SWIMMING POOL, SPA, AND HOT TUB CODE
2021 UNIFORM MECHANICAL CODE
2020 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 1
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 0
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 5
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- All Jobs
- Allowed POI
- Line Side Taps,PV Breaker,Load Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- No
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Electrical load calcs required for ALL projects. (even for MPU) For our PM a 200 amp metercan with bypass is required for XCEL ENERGY UTILITY.
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- No