County of Sandoval (NM)
NEC Code Version2020
Wet Stamps RequiredDigital Structural
Fire Setback Enforced0
Codes
- NEC Code Version
- 2020
- Code List
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL RESIDENTIAL CODE
2020 NATIONAL ELECTRIC CODE
2021 NEW MEXICO RESIDENTIAL BUILDING CODE
2021 NEW MEXICO EARTHEN BUILDING MATERIALS CONSTRUCTION CODE (PHASE III)
2009 NEW MEXICO NON-LOAD BEARING BALED STRAW CONSTRUCTION BUILDING CODE (PHASE III)
2021 NEW MEXICO RESIDENTIAL ENERGY CONSERVATION CODE
2021 NEW MEXICO EXISTING BUILDING CODE
2021 NEW MEXICO HISTORIC EARTHEN BUILDINGS
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
Fire setbacks
- Fire Setback Enforced
- 0
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category C
- Snow Load
- 5
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- All Jobs
- Allowed POI
- Line Side Taps,Meter Adapter,PV Breaker,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Electrical load calcs required for ALL projects. (even for MPU)
- Cover Page
If home is a manufactured home, add this to the codes '2023 PART 3280-MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS'
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim