State of New Mexico - Manufactured Housing (CID) (NM)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2020 NEW MEXICO ELECTRICAL CODE
2020 NATIONAL ELECTRICAL CODE
2012 NATIONAL ELECTRICAL SAFETY CODE
2021 NEW MEXICO BUILDING CODE
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL RESIDENTIAL CODE
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 NM EARTHEN BUILDING CODE
2021 NM HISTORIC EARTHEN BUILDING CODE
2021 ENERGY CONSERVATION CODE
2021 UNIFORM MECHANICAL CODE
2024 CFR PART 3280 BUILDING CODES - MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 1
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Ridge Setback
- 36
- Rake Setback
- 36
- Eave Setback
- 13
- Setback Notes
- Fire setback on plans must be from ridge cap to top of panels, not spanning ridge cap.
- 36 inches from ridge cap not to overlap the ridge.
Structural & loads
- Wind Speed
- 85
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Ref CFR 3280 or NMAC for MH only under Design Criteria Code in PE letter/calcs. Must state verbatim "CFR PART 3280 BUILDING CODES - MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS"
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- Yes
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Meter Adapter,Line Side Taps,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Per MHD inspector going forward no new electrical equipment can be mounted on a manufactured home regardless if service panel is already mounted, all new equipment must be on a H frame. The only electrical equipment allowed is a DC disconnect.
Please be advised truss layout is individual basis. Needs to be project specific.
Add ECO 44 specs please do not use ECO 65 If the main panel is on the pole the AC disconnect needs to be within 5 ft, if greater than 25ft additional AC disconnect will be required outside the home DO NOT ADD FLASH KIT PRO ON THE ATTACHEMENTS.
Our P< and Ac disco has be within 5 ft of the UM and add an additional disco on the exterior of the mobile home. Per Inspector communication with BM POI is not allowed in subpanel.
- Cover Page
2024 CFR PART 3280 BUILDING CODES - MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS
- Site
https://www.srca.nm.gov/parts/title14/14.012.0005.html
- Site Notes
- Manufactured Housing codes on stamped plans or engineering codes,
- The calcs/plans are not clear on deck mounting or stringer mounting (metal roof).
- Plans show both and calcs
- Roof Plan
Manufactured housing requires a 36-inch fire egress from the ridge of the home.
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim