Village of Los Lunas (NM)
NEC Code Version2020
Wet Stamps RequiredNone
Fire Setback Enforced0
Codes
- NEC Code Version
- 2020
- Code List
2021 New Mexico Building Code
2021 International Building Code
2021 International Residential Code
2020 New Mexico Electrical Code
2020 National Electrical Code
2012 National Electrical Safety Code
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 1
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- None
- Structural Calculations Required
- No
Fire setbacks
- Fire Setback Enforced
- 0
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category C
- Snow Load
- 6
- Reducible Snow Load Allowed
- 0
- Max Attachment Spacing
- 96
- Structural Notes
- Structural analysis must be performed by a professional engineer licensed in New Mexico to determine if the roof structure is capable of supporting the added loads of a solar PV electric system when any of the following occur: * The total added dead load of the array is greater than five pounds per square foot on the roof. For manufactured/mobile home projects, include the following codes on the engineer letter/calcs: CFR PART 3280 BUILDING CODES - MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS AS ADOPTED BY NM MHD
Electrical
- Allowed POI
- Meter Adapter,Load Side Taps,Line Side Taps,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Additional permits are required through CID New Mexico (NM). Please see page for design requirements.
Structural calculations required for ballast mount projects per Rework
- Cover Page
For manufactured/mobile home projects, include the following codes on code list notes: CFR PART 3280 BUILDING CODES - MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS AS ADOPTED BY NM MHD
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim