City of North Las Vegas (NV)
Codes
- NEC Code Version
- 2017
- Fire Code Version
- 2018 Building Code
- Code List
2018 INTERNATIONAL ENERGY CONSERVATION CODE
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL EXISTING BUILDING CODE
2018 INTERNATIONAL RESIDENTIAL CODE
2018 UNIFORM MECHANICAL CODE
2018 UNIFORM PLUMBING CODE
2017 NATIONAL ELECTRICAL CODE
2018 INTERNATIONAL SWIMMING POOL AND SPA CODE
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Ee Stamp Notes
EE stamped Load Justification Letter / Calcs if 12 months of consecutive usage is not present. EE stamp needs to be sized at 1 - 11/16 per NV state law.
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- All Jobs
- Allowed POI
- Meter Adapter,PV Breaker,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.87
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
AHJ: City of Henderson (NV). Utility Co: NVEnergy - Nevada Energy. Battery needs to be installed in garage. [a past project. DCR 063020]
Relocate battery meter socket & disconnect switch to the battery branch leg of the PV circuit with battery socket closest to the batt storage unit. There shall be no meter socket/disc switch at where the backup panel is located (AC coupled system). Batt > PM > Disco > Combiner
- Separate ESS Disconnect Required
- Local Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Make sure we are not referencing the CEC, 2014 NEC, anywhere in the plans
Load Calcs required on all projects
AHJ Requirements state plans must:
· Be EE stamped
· Have Load Calculations
- Site Notes
All Jobs [P/V equipment - Structural elements where the additional dead load from the roofing or equipment does not increase the force in the element by more than 5 percent]
- Roof Plan Notes
All Jobs [THE HIGHEST POINT OF THE PV ARRAY SHALL NOT EXCEED SIX (6) FEET BEYOND THE EXISTING ROOF ONTO WHICH IT IS MOUNTED]
- Electrical Diagram
No Line side Tap are allowed, except on Listed Solar Ready Panel Centerfed 120% allowed
- Label Page Notes
Labels and markings for the photovoltaic systems will be reflective and meet all the requirements per NFPA 1 sect 11.12
- Custom Placards Required
- 1
- Non Standard Revision Requirements
For REVISIONS, red cloud all changes made to the plans and add the revision letter of the changes.
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim