County of Lane (OR)
Codes
- NEC Code Version
- 2023
- Code List
2022 OREGON STRUCTURAL SPECIALTY CODE
2022 OREGON SOLAR INSTALLATION SPECIALTY CODE
2023 OREGON RESIDENTIAL SPECIALTY CODE
2025 OREGON ENERGY EFFICIENCY SPECIALTY CODE
2023 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 2
- Revision Required
- 1
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 0
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 120
- Snow Load
- 999
- Snow Load Notes
Minimum is 25psf, roof load. Elevations above 500 ft need to be calculated
- Reducible Snow Load Allowed
- 0
- Max Attachment Spacing
- 48
- Structural Notes
If not using Prescriptive Path design method on layout (Prescriptive Path Checklist attached), then SE stamps will be required for Roof Mounts.
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates,Load Relocation
- Allowed POI
- Load Side Taps,PV Breaker,Line Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
ESS disconnect required within 6ft of MSP on same wall and not blocked by walls/gates/etc
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- Yes - with dimensions
Plan set
- Plan Set Requirements
- If not using Prescriptive Path design method on layout (Prescriptive Path Checklist attached), then SE stamps will be required for Roof Mounts.
Engineer scale cannot be done with fractions (ex. 1/8" = 1'). Per AHJ, engineer's scale goes to the 10th rather than a fraction
Accepted engineerβs scales end in zero
(1β=60β or 1β=50β, for example)
- All SolarApp+ project will need whole home load calculations. (PV, PV+ESS, Backup, Non-backup)
- Site
Use this website to determine property dimensions : (https://www.lanecounty.org/cms/One.aspx?portalId=3585881&pageId=4196390)
- Attachment Detail
Attachments shall be spaced not greater than 24 inches (609.6 mm) on center in any direction where: * Ground snow loads (https://up.codes/viewer/oregon/ibc-2018/chapter/2/definitions#loads_455.715_definitions_for_ors_455.715_to_455.740) exceed 36 psf (1.197 kN/m2). * Located within 3 feet (914 mm) of a roof edge, hip, eave or ridge. * Located in wind Exposure Category B or greater and the _wind speed_ exceeds 120 mph. * Located in wind Exposure Category C or greater and the _wind speed_ exceeds 110 mph.
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
Property line must match what the AHJ has on file. Either search the County's GIS tool, or reach out to the AHJ for a map. Zoning Dept: To avoid multiple months of delays in permitting and zoning approval, keep the GM within 142ft of the residence. Scale of plans should be in standard engineer scale (ie. 1β = 10β,20β,30β,40β,50β,60β 1β = 100β,200β,300β,400β)
- Setback Front Yard
- 30
- Setback Back Yard
- 30
- Setback Side Yard
- 30