County of Malheur (OR)
NEC Code Version2023
Fire Code Version2018 Building Code
Wet Stamps RequiredNone
Fire Setback Enforced1
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2022 OREGON STRUCTURAL SPECIALTY CODE
2023 OREGON RESIDENTIAL SPECIALTY CODE
2025 OREGON ENERGY EFFICIENCY SPECIALTY CODE
2023 OREGON ELECTRICAL SPECIALTY CODE
2022 OREGON MECHANICAL SPECIALTY CODE
2023 OREGON PLUMBING SPECIALTY CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 1
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- None
- Structural Calculations Required
- No
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
No pathways allowed within 12 of the low point of a valley. Pathways must be over a structurally supported area. They cannot be placed on an eave.
Structural & loads
- Wind Speed
- 101
- Wind Notes
https://ascehazardtool.org/
- Snow Load
- 40
- Snow Load Notes
https://ascehazardtool.org/
.
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Structural Notes
- No structural required if we abide by OSSC 3111.5.3 Manufactured homes require structural calculations. "Attachments must be spaced no greater than 48" on center in any direction. Attachments shall be spaced no greater than 24" on center in any direction where: (3.2.) located within 3 feet of a roof edge, hip, eave, or ridge."
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,Load Side Taps,PV Breaker,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Roof Plan
**01/10/2023 - AHJ let us know we need to add fire setbacks to the plans**
- Attachment Detail
Attachments shall be spaced not greater than 24 inches (609.6 mm) on center in any direction where:
- Ground snow exceed 36 psf (1.197 kN/m2).
- Located within 3 feet (914 mm) of a roof edge, hip, eave or ridge.
- Located in wind Exposure Category B or greater and the wind speed exceeds 120 mph.
- Located in wind Exposure Category C or greater and the wind speed exceeds 110 mph.
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
Ground mounts must be 15' away from all property lines and 40' from right of way. This needs to be marked on plans.
- Setback Front Yard
- 15
- Setback Back Yard
- 15
- Setback Side Yard
- 15