City of West Greenwich (RI)
Codes
- NEC Code Version
- 2017
- Fire Code Version
- 2018 Building Code
- Code List
2017 NATIONAL ELECTRICAL CODE 2021 RHODE ISLAND STATE BUILDING CODE 2021 RHODE ISLAND RESIDENTIAL CODE 2021 RHODE ISLAND FIRE CODE 2021 RHODE ISLAND PLUMBING CODE 2021 RHODE ISLAND MECHANICAL CODE 2021 RHODE ISLAND ENERGY CODE 2021 RHODE ISLAND ADMINISTRATIVE CODE 2021 RHODE ISLAND ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 2
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
SE / EE digital stamps on all PV pages 1-7a & PE Letters / Calcs.
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Ground Mounts-
Dimensional regulations for ground-mounted solar energy systems.
(1) The maximum height of a ground-mounted solar energy system shall be 12 feet, with the exception of solar-covered parking structures, which shall have a maximum height of 18 feet from the ground. The height shall be measured from the ground level or the base of the system's pedestal to the highest point of the solar energy system, including the top of any support structure or panel. A maximum of six feet of fill shall be permitted, and a dimensional variance shall be required for projects proposing more than six feet of fill.
(2) Setbacks.
(a) A solar energy system that is accessory to a principal structure may be located no closer than 1/2 of the setback that would otherwise apply or 20 feet from the front, side, or rear site lines, whichever is greater.
(b) A limited solar energy system shall have a setback requirement of 200 feet from adjacent residential zoning districts and from the front yard line. Where the subject property borders a nonresidential zoning district, the setback shall be 50 feet.
(3) Lot coverage. A limited solar energy system shall cover no greater than 50% of a lot or contiguous lots in common ownership. The lot coverage calculation shall include inter-row and panel/collector spacing, meaning that the entire area of the installation shall be counted as lot coverage.
Structural & loads
- Wind Speed
- 135
- Wind Notes
Exposure Category C. Wind-borne debris region.
- Snow Load
- 30
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,Line Side Taps,PV Breaker,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim