Town of Tiverton (RI)
NEC Code Version2017
Wet Stamps RequiredDigital Structural,Digital Electrical
Fire Setback Enforced1
Codes
- NEC Code Version
- 2017
- Code List
2021 RHODE ISLAND STATE BUILDING CODE 2021 RHODE ISLAND RESIDENTIAL CODE 2021 RHODE ISLAND FIRE CODE 2021 RHODE ISLAND PLUMBING CODE 2021 RHODE ISLAND MECHANICAL CODE 2021 RHODE ISLAND ENERGY CODE 2021 RHODE ISLAND ADMINISTRATIVE CODE 2021 RHODE ISLAND ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 1
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
SE / EE digital stamps on all PV pages 1-7a & PE Letters / Calcs. WS 138 SL 30 Exposure Category C. Wind-borne debris region.
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
On pitched roofs, solar panels shall be set back a minimum of 18 inches from **all roof edges.** On flat roofs, SES (solar energy systems) shall be set back from the edge at least two feet.
Structural & loads
- Wind Speed
- 138
- Wind Notes
Exposure Category C. Wind-borne debris region.
- Snow Load
- 30
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,Load Side Taps,PV Breaker,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim