City of Frisco (TX)

Texas Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2023
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural,Digital Electrical
Fire Setback Enforced1

Codes

NEC Code Version
2023
Fire Code Version
2018 Building Code
Code List

2021 INTERNATIONAL BUILDING CODE (IBC)

2021 INTERNATIONAL MECHANICAL CODE (IMC)

2021 INTERNATIONAL PLUMBING CODE (IPC)

2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)

2021 INTERNATIONAL RESIDENTIAL CODE (IRC)

2021 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC)

2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC)

2021 INTERNATIONAL FUEL GAS CODE (IFGC)

2021 INTERNATIONAL FIRE CODE (IFC)

2023 NATIONAL ELECTRICAL CODE (NEC)

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

How Many Plansets Required
1
Revision Required
1
New Planset Required For Module Swap
0

Stamps

Ee Stamp Required On SLD
Yes
Wet Stamps Required
Digital Structural,Digital Electrical
Structural Calculations Required
Yes
Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
1
Setback Notes

Standard

Structural & loads

Wind Speed
115
Wind Notes

Exposure Category B

Snow Load
5
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Structural Notes

EE stamp required on SLD. SE/EE digital stamps on corresponding PV pages & PE Letter / Calcs. WS: 115mph. Exposure B. SL: 5psf

Minimum Ground On Roof
#10

Electrical

AC Disconnect Required
Yes
Electrical Load Calcs Required
Derates
Allowed POI
Meter Adapter,Load Side Taps,Line Side Taps,PV Breaker
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
0.96
BOS Restrictions

Will need to install smoke/heat detectors for the batteries in the garage

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Will need to install smoke/heat detectors for the batteries in the garage. They will need to be interconnected with the existing fire alarm system smoke combos

Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Plan Set Requirements

EE stamp required on SLD. PE stamp required on other PV pages, on PE letter and on Structural Calcs. [a past project. DCR 080221]

Site Notes

Total roof sq ft and total array sq ft required

Electrical Diagram

TAPS

The city of Frisco does not accept the B-TAPs for line side connections, they only accept IT-350 Polaris Blocks for line side terminations.

When calling out a line side tap one of the two following builds should be designed, based on the as-built conditions.

Meter can ONLY outside (readily accessible):

  • (N) non fusible disconnect outside next to meter to serve as the emergency disconnect (NEC 2020: 230.85) .
  • Show two port lugs on the line in side of the disconnect with the inverter/combined inverters output terminated on the second port (first port tied to the utility supply).
  • Include all subsequent parts in BOM

Meter can AND disconnect located outside (readily accessible):

  • Perform a Hoffman/tap box tap at the existing disconnect.
  • Indicate on single line that the tap connecters used are Polaris IT-350 and clearly show tap in the junction box NOT the disconnect.
  • Include the confirmation letter in the files section
  • Include all subsequent parts in the BOM
Electrical Diagram Notes

Will need to install smoke/heat detectors for the batteries in the garage. They will need to be interconnected with the existing fire alarm system smoke combos

Custom Placards Required
1
Placards Notes
  • Frisco Requires placards to be installed at time of inspection. If placard is not installed and visible, it will fail inspection
Non Standard Planset Requirements
Single Line Diagram

Ground mount

Ground Mount Fencing Required
Mesh/Scrim
Compiled from public records, 2026. Requirements change with code cycles and local amendments. Verify with the City of Frisco (TX) building department before you rely on this, and treat it as a research head start, not a ruling. Getting quotes? Run them through the quote checker first.