City of Lubbock (TX)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL RESIDENTIAL CODE
2021 INTERNATIONAL PLUMBING CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL RESIDENTIAL CODE
2021 INTERNATIONAL FUEL GAS CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2021 INTERNATIONAL PLUMBING CODE
2021 INTERNATIONAL FIRE CODE
2020 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 1
- Revision Required
- 1
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
- ENGINEER SIGNED AND SEALED DRAWINGS FOR PANEL ATTACHMENTS AND ELECTRICAL CALCULATIONS
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
On a pitched roof that is visible from the public right-of-way (the street in front of the house), the array may cover a maximum of 50% of the roof plane visible to the public right-of-way.
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure category C
- Snow Load
- 15
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
- PLAN SUBMITTALS MUST INCLUDE ENGINEER SIGNED AND SEALED STRUCTURAL LETTER VERIFYING THE EXISTING STRUCTURE IS ABLE TO WITHSTAND ADDITIONAL WEIGHT AND WIND RESISTANCE FROM ROOF MOUNTED SOLAR PANEL SYSTEM
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,Load Side Taps,Meter Adapter,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
- Roof Plan
- Roof Plan Notes
Roof planes facing the street cannot exceed over 50% panel coverage. Provide individual roof plane coverage if facing the street
EX:
Front Roof Face: 1000 sqft
Front Array: 100 sqft
Array Coverage: 10%
EXAMPLE
- Custom Placards Required
- 1
- Placards Notes
trenching is not needed the fact that LP&L And SPEC allow us to use mapplacards instead of trenching.
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim