City of Murphy (TX)
NEC Code Version2020
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2021 INTERNATIONAL FIRE CODE
2021 INTERNATIONAL FUEL GAS CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL PLUMBING CODE
2021 INTERNATIONAL RESIDENTIAL CODE
2020 NATIONAL ELECTRIC CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 5
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- Yes
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,Load Side Taps,Line Side Taps,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Electrical Diagram
Standard
- Custom Placards Required
- 0
- Placards Notes
- Inspections Inspections called in before 3 p.m. will go out the next business day, excluding holidays. The Inspection Line is . Registered contractors can create an online account to schedule inspections. If cancelling an inspection, you must before 9:00 a.m. and speak to a live person. Any cancellations left on the voicemail will still go out for inspection and could result in fees being charged. Same-day inspections/re-inspections are subject to an additional fee. This includes inspections called in after 3 p.m. cut-off time. Payment is due prior to inspection request being made. Please include the following information when calling for an inspection: Builder’s name Contact person name and phone number Inspection address Permit Subdivision Name Inspection requested The site is assumed ready for inspection at the time of your inspection request unless otherwise noted. Please specify if you are requesting a re-inspection when calling. Inspections will not be made when work is in progress. The inspection request line is accessible 24 hours a day by calling . The inspection line is dedicated solely for inspection requests, all other calls should be made to Customer Service at . View additional information regarding permits (https://www.murphytx.org/index.aspx?NID=116).
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim