City of Wichita Falls (TX)

Texas Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2020
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1

Codes

NEC Code Version
2020
Fire Code Version
2018 Building Code
Code List

2015 INTERNATIONAL RESIDENTIAL CODE

2015 INTERNATIONAL BUILDING CODE

2015 INTERNATIONAL EXISTING BUILDING CODE

2015 INTERNATIONAL PLUMBING CODE

2015 INTERNATIONAL MECHANICAL CODE

2015 INTERNATIONAL FUEL GAS CODE

2015 INTERNATIONAL FIRE CODE

2006 INTERNATIONAL ENERGY CODE

2020 NATIONAL ELECTRIC CODE

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

Revision Required
1
Rough Inspection
Rough Electrical
New Planset Required For Module Swap
1

Stamps

Wet Stamps Required
Digital Structural
Structural Calculations Required
Yes
Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
1
Setback Notes

## 2015 IFC: _ **Hip Roof layouts**_ : 3 ft wide clear access pathway from the eave to the ridge on each roof slope where the panels and modules are located. _ **Single Ridge Roofs**_ : 3 ft wide access pathways from the eave to the ride on each roof slopes where panels and modules are located. _ **Roof with Hips and Valleys:** _18 inches to a hip or valley where panels/modules are to be placed on both sides of a hip or valley that is of equal length, the panels shall be permitted to be placed directly adjacent to the hip or valley.

Structural & loads

Wind Speed
115
Wind Notes

Exposure Category B

Snow Load
5
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Structural Notes

Flatten Plans PDF / Remove Layers prior to sending to engineer for stamps. SE digital stamps on corresponding PV pages, PE Letter & Calcs. WS: 115MPH, Exposure Cat. B, GSL: 5LBS

Minimum Ground On Roof
#10

Electrical

Electrical Load Calcs Required
Derates
Allowed POI
PV Breaker,Load Side Taps,Line Side Taps,Meter Adapter
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
0.91

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Standard

Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Plan Set Requirements

2015 IFC: Each photovoltaic array shall be limited to 150 ft by 150 ft. Multiple arrays shall be separated by a 3ft wide clear access pathway. Hip Roof layouts: 3 ft wide clear access pathway from the eave to the ridge on each roof slope where the panels and modules are located. Single Ridge Roofs: 3 ft wide access pathways from the eave to the ride on each roof slopes where panels and modules are located. Roof with Hips and Valleys: 18 inches to a hip or valley where panels/modules are to be placed on both sides of a hip or valley that is of equal length, the panels shall be permitted to be placed directly adjacent to the hip or valley. Flatten PDF plans / remove layers before sending to PE for stamps.

Attachment Detail

Each photovoltaic array shall be limited to 150 ft by 150 ft. Multiple arrays shall be separated by a 3ft wide clear access pathway.

Electrical Diagram

When adding a new Meter Can it must have a metallic bond from PVC riser to the can

Custom Placards Required
0

Ground mount

Ground Mount Fencing Required
Mesh/Scrim