County of San Juan (UT)
NEC Code Version2020
Fire Code Version2018 Building Code
Fire Setback Enforced1
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2021 International Building Code, including Appendix J, issued by the International Code Council 2020 National Electrical Code issued by the National Fire Protection Association 2021 International Mechanical Code issued by the International Code Council 2021 International Plumbing Code issued by the International Code Council 2021 International Fuel Gas Code issued by the International Code Council The residential provisions of the 2021 International Energy Conservation Code issued by the International Code Council
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Wind Load: 115 mph exposure โCโ
- Snow Load
- 999
- Snow Load Notes
Varies in this area by geography
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,Line Side Taps,PV Breaker,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim