Solar Sanity Checksolar, decoded Independent. Nothing you type leaves your browser.

City of Hampton (VA)

Virginia Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2020
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1

Codes

NEC Code Version
2020
Fire Code Version
2018 Building Code
Code List

2021 VIRGINIA RESIDENTIAL CODE

2020 NATIONAL ELECTRICAL CODE

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

How Many Plansets Required
Other (See Submission Notes)
Revision Required
1
New Planset Required For Module Swap
0

Stamps

Wet Stamps Required
Digital Structural
Structural Calculations Required
Yes
Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
1
Setback Notes

State Code should be referenced as VRC _**_not_ **_VARC, The City of Hampton requires what the Virginia Statewide Fire Prevention Code requires. The current Virginia Statewide Fire Prevention Code Section 1204 provides the requirements on the required setbacks as well as aisles from base of the roof to the peak. These distances are to be clearly shown on the submitted plans. Please keep in mind that any roof penetrations (ducts, vents, flues, chimneys) cannot encroach into these defined areas.

Structural & loads

Wind Speed
115
Wind Notes

Exposure Category B

Snow Load
15
Snow Load Notes

2021 VRC only

Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Structural Notes

Revised layouts and mod swaps will require new PE stamps and PE calcs/letter. The current VRC is the only code that should be referenced in PE documents

Minimum Ground On Roof
#10

Electrical

Electrical Load Calcs Required
Derates
Allowed POI
Meter Adapter,Load Side Taps,Line Side Taps,PV Breaker
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
0.91

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Standard

Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Custom Placards Required
0

Ground mount

Ground Mount Fencing Required
Mesh/Scrim
Compiled from public records, 2026. Requirements change with code cycles and local amendments. Verify with the City of Hampton (VA) building department before you rely on this, and treat it as a research head start, not a ruling. Getting quotes? Run them through the quote checker first.