City of Winooski (VT)

Vermont Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2017
Fire Setback Enforced0

Codes

NEC Code Version
2017
Code List
2015 VERMONT FIRE AND BUILDING SAFETY CODE 2017 VERMONT ELECTRICAL SAFETY RULES 2018 VERMONT PLUMBING RULES 2014 VERMONT ELEVATOR SAFETY RULES 2012 VERMONT ACCESS RULES 2015 NFPA 1 FIRE CODE 2015 NFPA 101 LIFE SAFETY CODE 2015 INTERNATIONAL BUILDING CODE 2017 NFPA 70 NATIONAL ELECTRICAL CODE 2018 INTERNATIONAL PLUMBING CODE 2015 THE NATIONAL BOARD INSPECTION CODE
ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

How Many Plansets Required
Other (See Submission Notes)
Revision Required
0
New Planset Required For Module Swap
0

Fire setbacks

Fire Setback Enforced
0
Setback Notes
Standard

Structural & loads

Wind Speed
115
Wind Notes

Exposure Category B

Snow Load
50
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Minimum Ground On Roof
#10

Electrical

Electrical Load Calcs Required
Derates
Allowed POI
Meter Adapter,Load Side Taps,PV Breaker,Line Side Taps
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
0.91

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes
Standard
Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Plan Set Requirements
Electrical load calcs required for ALL projects. (even for MPU)

Ground mount

Ground Mount Fencing Required
Mesh/Scrim
Compiled from public records, 2026. Requirements change with code cycles and local amendments. Verify with the City of Winooski (VT) building department before you rely on this, and treat it as a research head start, not a ruling. Getting quotes? Run them through the quote checker first.